TROUBLESHOOTING
This device integrates a default management system. In the event of a default, error messages may be displayed.
Error code
Meaning
CAUSES
SOLUTIONS
Thermal protection
"Exceeding the duty cycle
Ambient temperature above 40°C
Blocked air inlets
"
"Wait for the indicator to turn off before resuming
welding operations.
Observe the operating factor and ensure good
ventilation"
Mains overvoltage fault
Mains voltage outside maximum tolerance
Have the sensors connection checked by a qualified
person.
«UE1»
Mains undervoltage fault
Mains voltage outside minimum tolerance
Have your electrical installation checked by a qua
-
lified person. The mains voltage must be between
95Vrms and 265Vrms.
«UE2»
Fan fault
The fan is not running at the right speed.
Check for foreign bodies that could slow down the
fan, check the correct wiring, replace the fan
«HE1»
Power relay control fault
The power relay could not be closed
Have the wiring of the relay control system checked
by qualified personnel
«HE2»
Settings memorisation fault
The EEPROM memory is defective
Contact your reseller
«HE3»
No temperature information The temperature sensors are disconnected
Have the sensor wiring checked by qualified staff
«HE4»
Defective keyboard buttons
One or more buttons on the keyboard are
permanently short-circuited
Replace the keyboard
«SE»
Software Error
Communication problemn
Contact your reseller
All operations requiring the removal of the machine’s cover and checking the electrical systems must be done by a qualified technician.
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase (parts and labour).
The warranty does not cover:
• Transit damage.
• Normal wear of parts (eg. : cables, clamps, etc..).
• Damages due to misuse (power supply error, dropping of equipment, disassembling).
• Environment related failures (pollution, rust, dust).
In case of failure, return the unit to your distributor together with:
- The proof of purchase (receipt etc ...)
- A description of the fault reported.
Содержание 014657
Страница 51: ...51 PROGYS 220E FV CEL RU 10 40 C 14 104 F 20 55 C 4 131 F 50 40 C 104 F 90 20 C 68 F 1000 3280 10...
Страница 52: ...52 PROGYS 220E FV CEL RU 11 2 A CEI 61000 3 12 Zmax 0 246 IEC 61000 3 11 C EMF EMF...
Страница 53: ...53 PROGYS 220E FV CEL RU b c d e f g h 10 CISPR 11 2009 a b c d e f 10...
Страница 62: ...62 PROGYS 220E FV CEL RU 40 C UE1 95Veff 265Veff UE2 HE1 HE2 EEPROM HE3 HE4 SE 2...
Страница 92: ...92 SAS GYS 1 rue de la Croix des Landes CS 54159 53941 SAINT BERTHEVIN Cedex France...