OPERATION
83
IPK Limit
On/Off
In theory, It is the function which keeps the IPK
limits (+ & -) within the certain range when the
predefined values are reached. If, however, this
function is turned off, the output will be disabled
instantly when either IPK+ or IPK- limit is reached.
4.
Press Enter to confirm the peak current setting.
Note
IPK Limit is set ON by default.
Setting the Output Current Level
Background
The IRMS and I settings set the current of the
output. Setting the RMS or AVG current sets a limit
on the current that can be sourced by the power
supply. Once the output current is over the setting,
the output will set to off.
Steps
1.
Press
Irms
to access the IRMS or I
menu depending on varied modes.
Also, it is available to use the scroll
wheel followed by the Enter key to
make the IRMS or I parameter
selectable as well.
2.
Set the IRMS/I level with the scroll wheel or
with the F3 ~ F4 soft-keys. The MAX and MIN
soft-keys set the IRMS or I level to the
maximum and minimum, respectively.
AC+DC-INT, AC–INT, DC-INT, AC+DC-EXT,
AC–EXT, AC+DC-ADD, AC–ADD, AC+DC-
Sync, AC-Sync, AC-VCA
IRMS/I
Range
5% ~ 105% of rate current
Soft-keys
IRMS Limit On/Off, MAX,
MIN
Содержание ASR-2000 Series
Страница 1: ...Programmable AC DC Power Source ASR 2000 Series USER MANUAL ISO 9001 CERTIFIED MANUFACTURER ...
Страница 11: ...GETTING STARTED 11 ...
Страница 130: ...ASR 2000 Series User Manual 130 Example Power ON setting ...
Страница 216: ...ASR 2000 Series User Manual 216 ASR 2000 Dimensions ASR 2100 2050 Scale mm ...
Страница 217: ...APPENDIX 217 ASR 2100R 2050R Scale mm ...
Страница 218: ...ASR 2000 Series User Manual 218 ASR 2100R 2050R with GET Series Box Scale mm ...
Страница 219: ...APPENDIX 219 GET 003 Series Box GET 004 Series Box ...