ASR-2000 Series User Manual
142
Sequence Mode
Sequence Mode Overview
Background
The Sequence function works with DC-INT, AC-
INT and AC+DC-INT modes with full AC
waveforms containing sine, square, triangle as well
as arbitrary. The available parameters, which will be
introduced in later sectors, vary depending on
selected output modes.
A Sequence function is comprised of up to the
maximum 999 steps.
Setting Screen
Overview
Test Mode
V RANGE
Recall Test
Save Test
Run Test
Branch 2
Sync Code
Branch 1
Step Termination
On Phase
Off Phase
DC Voltage
AC Voltage
Step Number
Step Time
Frequency
Waveform
Jump To
Jump Count
Sequence
Parameter
Overview
The Sequence function is comprised of a minimum
of 2 steps that are executed in user defined
sequences.
Each step can have different step time, voltage level,
start & stop phase, frequency and wave.
Note
Step 0 is assigned as a “Standby” step. At the end of
the test the unit will shift to the standby step.