ASR-2000 Series User Manual
160
Trans1
This step configures the transition
from normal to abnormal conditions.
This step will linearly interpolate the
normal settings to the abnormal
settings. This step can be skipped for
abrupt state changes.
Abnormal
This step contains the abnormal
conditions for the simulation.
Trans2
This step configures the transition
from abnormal to normal conditions.
Normal2 This step configures the normal
conditions that supersede the
abnormal conditions.
Abnormal
Trans1
Normal1
Init
Trans2 Normal2 Init
Parameter
Overview
The following table shows which parameters are
available for each step.
Step\Parameter Initial Normal1 Trans1 Abnormal Trans2 Normal2
Time
X
✓
✓
✓
✓
✓
ACV
✓
✓
X
✓
X
X
ON Phs
✓
✓
X
✓
X
✓
Fset
✓
✓
X
✓
X
X
OFF Phs
✓
✓
X
✓
X
✓
Wave
✓
✓
X
✓
X
X
Code
✓
✓
✓
✓
✓
✓
Repeat
✓
✓
✓
✓
✓
✓