ASR-2000 Series User Manual
76
Note
1. Vrms can only be set up to 144.3 Vrms / 288.6 Vrms
for triangular waveform.
2. Go to Menu -> MISC -> V Unit to select the voltage
set value unit.
Setting the Frequency Limit
Background
Setting the frequency limit allows the frequency
output to be set to any level within the limit
range.
Steps
1.
Press
Shift + F
to access the Freq
Limit menu.
+
2.
Use the scroll wheel to toggle between Freq Hi
(upper) and Freq Lo (lower) settings followed
by pressing
Enter
to get into the parameter.
Freq Hi
Setting
Freq Lo
Setting
3.
Set the frequency limit with the scroll wheel or
with the F3 ~ F4 soft-keys. The MAX and MIN
soft-keys set the frequency limit to the
maximum and minimum, respectively.