Dynamic Real Time Temperature Measurement
•
Palette lies at the bottom of the screen, with its upper and lower limits displayed at
the two ends.
•
Two temperatures are present just above the palette. The first one indicates the
lowest temperature, and the second indicates the highest scene temperature.
There are two arrows on the palette, which indicate the specific color
corresponding to the lowest and highest temperature respectively.
•
The center temperature is displayed in top of the screen.
Setting the temperature range
•
There are two modes available, Auto and Manual
•
To switch between one mode and another keep Button “
●
” depressed for three
seconds, the current mode is displayed temporarily on the screen after the button
is released
•
Within Auto or Manual mode the setup parameters menu can be brought up, this
is achieved by pressing Button “
●
” for an instant in either mode. The item
which can be modified will be highlighted.
•
Press
“ ”and“ ”
∧
∨
to change value when the upper or lower limits of the palette is
highlighted, to shift between different palettes from 1 to 8 when palette is
highlighted and to shift between Auto Mode and Manual Mode when highlighted
•
Press
“
>
” to shift between each item in turns counter-clockwise.
•
Press
“
<
” to shift between each item in turns clockwise.
•
In Auto Mode, if you highlight the upper or lower limits of the palette and press
“ ”and“ ”
∧
∨
to change its value, the mode will change to Manual Mode
automatically.
•
Press either OK or C to confirm the modification.