I
The oil level rises w ithout oil
being added
Condensation w ater accumulates in oil
Compressor is overdesigned, notify the Güde
Service
High air humidity
Replace the oil
J
Compressor is overheated and
it sw itches off
Compressor is overloaded
Notify the Güde Service
Compressor is faulty
Notify the Güde Service
Compressor has under voltage
Notify the Güde Service
Ambient temperature 35°C
Notify the Güde Service
Maintenance Table
Maintenance periods are valid for norm al operating conditions; in case of
extrem e operating conditions the m aintenance periods are shortened correspondingly.
Actions
Periods
Date
Date
Date
Date
Intake suction filter check
• cleaning
• replacement
Weekly every
50 hours of operation,
min. once a year
Cleaning of reverse valve and insert
Yearly
Oil level check
Daily or more precisely before
every putting into operation
Oil replacement
1. replacement of mineral oil
of synthetic oil
after 50 hours of operation
once a year
every tw o years
Filling up/adding the oil
As required
Draining the condensation w ater from air
receiver
After every use
Draining the condensation w ater from
pressure reducing valve of the filter
After every use
Filter insert cleaning
As required
Compressor cleaning
As required
Screw ing check
First time after 10 hrs. of
operation, subsequently every
500 hrs. of operation
15