![Guardian MIZCS Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/guardian/mizcs/mizcs_installation-manual_2276751017.webp)
Guardian Telecom Inc.
Installation Programming Operation
Merge/Isolate Zone Control System
Page 17
The following table describes the MICAB registers and functions:
Register code
Function
Description
Parameter
Default Settings
Reg06
Master MICAB
Always exists
1 = exists
1
Reg07
MICON station #1
Assertion of its
existence in the
system
(Note 1)
0 = not installed
1 = installed
1
Reg08
MICON station #2
Assertion of its
existence in the
system
(Note 1)
0 = not installed
1 = installed
0
Reg09
MICON station #3
Assertion of its
existence in the
system
(Note 1)
0 = not installed
1 = installed
0
Reg10
MICON station #4
Assertion of its
existence in the
system
(Note 1)
)
0 = not installed
1 = installed
0
Reg11
MICON station #5
Assertion of its
existence in the
system
(Note 1)
0 = not installed
1 = installed
0
Reg12
MICON station #6
Assertion of its
existence in the
system
(Note 1)
0 = not installed
1 = installed
0
Reg13
Slave MICAB
Assertion of its
existence in the
system
(Note 1)
0 = not installed
1 = installed
0
Reg14 Merged
Time
(Note 2)
1-9 X 10 minutes
6
Reg15
Default Settings
Restoring the
MICON to the
default settings
(Note 3)
0, or 7 to restore
default settings
1
Notes:
1) All MICON stations and the MICAB slave units have to be programmed to indicate their existence
in the system. Any MICON station or MICAB slave that is not registered will not be polled by the
MICAB master unit.
2) The merged time is the maximum duration of zone merging since the last change. Once the time
runs out the merged zones will be isolated.
3) Setting Register 15 to 0 or 7 will restore all the registers back to the default settings in the MICAB.
3. Alarm Channel and the Associated Merged Zones setup
:
Press key [3] while in the main menu to program the MICAB Alarm function registers. Once key [3] is
selected the screen will display the MICAB Alarm register number and the setting. Enter or change the
zone that will be merged when the existing Alarm channel is activated.
Use the [VOL UP] or the [VOL DWN] to scroll through all the other registers.