MICAB Back Panel Connector Tables
(pin numbering is from left to right)
Power Input Connector
Aux. Alarm Input Connector
Pin #
Function
Pin #
Function
1
Neutral
1
Warning 1 - Dry contact input
2 Ground
2 Ground
3
Hot
3
Warning 2 - Dry contact input
4 Ground
Master / Slave Connector
Zone (1 - 5) Connectors
(Zone 6 -10 in Slave MICAB)
Pin #
Function
Pin #
Function
1
Merged Talk Line A
1
Isolated Talk Line A
2
Merged Talk Line B
2
Isolated Talk Line B
3
Merged Page Line A
3
Isolate Page Line A
4
Merged Page Line B
4
Isolate Page Line A
5
Data Signal A
6
Data Signal B
7 N/C
Alarm Logic Input Connector
(connected to AG17 Logic Outputs)
8 VDC
Ground
Pin #
Function
9
Mixed Signal A
1
Alarm I/P #1
10
Mixed Signal B
2
Alarm I/P #2
3
Alarm I/P #3
PTTI Connector
4
Alarm I/P #4
Pin #
Function
5
Alarm I/P #5
1
Merged Talk Line A
6
Alarm I/P #6
2
Merged Talk Line B
7
Alarm I/P #7
3
Merged Page Line A
8
Alarm I/P #8
4
Merged Page Line B
9
Alarm I/P #9
10
Alarm I/P #10
11
Alarm I/P Common
12
Alarm I/P Common
Alarm Logic Output Connector A
(connected to AG17 Logic Inputs)
Alarm Logic Output Connector B
(connected to AG17 Logic Inputs)
Pin #
Function
Pin #
Function
1
Alarm O/P #1
1
Alarm O/P #9
2
Alarm O/P #2
2
Alarm O/P #10
3
Alarm O/P #3
3
Alarm RST 2
4
Alarm O/P #4
4
Alarm Mute
5
Alarm O/P #5
5
Alarm O/P Common
6
Alarm O/P #6
6
Alarm O/P Common
7
Alarm O/P #7
7
Alarm Tone Input+
8
Alarm O/P #8
8
Alarm Tone Input-
9
Alarm RST 1
9
Alarm RST 1
10
Alarm Mute
10
Alarm Mute
11
Alarm O/P Common
11
Alarm O/P Common
12
Alarm O/P Common
12
Alarm O/P Common