background image

 

 

General Instructions and Care  

Inspection: 

 

Make sure unit is straight and operates smoothly. 

 

Make sure cable is not kinked, frayed or damaged. 

 

Make sure metal components are not damaged. 

 

Make sure toggle bar opens freely. 

 

Make sure the hole plug slides freely along main cable. 

 

Make sure the label is affixed to unit. 

 

When reusing a previously drilled hole, always inspect the hole carefully. 

 

Storage and Cleaning: 

 

After each use clean with compressed air. 

 

Store in clean dry environment. 

 

Store in secure area at the end of each work day. 

 

Do not pile objects unto or step on the unit. 

 

Keep unit free of grout, grease, oils and dirt or other contaminates. 

 

Never lend your unit to other workers. 

 

Disposal: 

 

Dispose of unit after any fall has occurred. 

 

Dispose of unit if cable becomes kinked or bent. 

 

Proper disposal requires the units main cable to be cut.

 

 

Follow all manufacturer’s instructions. 

 

Use only compatible connectors. 

 

Always inspect your units prior to use. 

 

Use the proper method of coupling to anchorage. 

 

Remove unit from service if a fall has occurred.  

 

Patch all holes with concrete when job is complete. 

 

For use by Single User only. 

 

Pregnant women and minors must not use this product. 

 

Designed safe working load is 400 LBS (149.3 kg). Do not exceed this weight. 

Important Warnings !!  

 

This product is to be used by qualified fall protection personnel only. It is to be anchored in accordance with  
manufacturer’s requirements.  All persons using this equipment must read and understand all instructions. Failure 
to do so may result in serious injury or death. If a fall occurs, the G-Lok must be disposed of according to the  
manufacturer instructions. Users should be familiar with regulations governing this equipment. All individuals who 
use this product must be correctly instructed before using this device.   
 
Use only compatible connectors with any G-Lok . Refer to separate instructions supplied with your connecting  
device. This product is designed for use in thin wall or hollow core precast concrete and steel flanges. 
 
Keep unit free of grout, grease, oils, dirt or other contaminates. This could effect the performance of the unit. 
 
When using a G-Lok make sure the Toggle Bar is activated in the open position ( See page 2 ).  

 
 

3

 

Содержание G-Lok

Страница 1: ...le Bar Swage Hole Plug Anchor Loop Activator Cable G Lok Part Description Main Cable 7x19 Aircraft Cable Ball Shank Stainless Steel Toggle Bar Stainless Steel Hole Plug 6061 T6 aluminum Spring Zinc Coated Stainless Steel Swage Zinc Coated Copper Return Wire 1x19 Aircraft Cable Anchor Loop Polyurethane Company Logo Hole Diameter Size Manufactured Date Batch Number Model Number ANSI Z359 1 Mark Warn...

Страница 2: ...le while pressing on the Cap As the unit passes through the hole the Toggle Bar will flip to the open position Dia B Shows the Toggle Bar open position Activating the Toggle Bar Dia A Dia B Thumb on Activator Cap while inserting Thumb pushing on Activator Cap forcing the Toggle Bar into open position Open position Insertion position 2 ...

Страница 3: ...ve unit from service if a fall has occurred Patch all holes with concrete when job is complete For use by Single User only Pregnant women and minors must not use this product Designed safe working load is 400 LBS 149 3 kg Do not exceed this weight Important Warnings This product is to be used by qualified fall protection personnel only It is to be anchored in accordance with manufacturer s require...

Страница 4: ...ill bits DO NOT USE masonry drill bits Drill a 3 4 diameter hole Drill hole in the center of core hollow Never drill hole closer than 6 to any edge or corner Always inspect a previously drilled hole for deformation Drill another proper hole if needed Inspect the unit for damage each time you use it If damage has occurred dispose of unit Make sure the Toggle Bar is activated in the open position Th...

Страница 5: ...nd ready to pull out The Toggle Bar must be in this parallel position when inserting and removing the unit Only when the unit is activated in the open position is it safe for load bearing Unit in insertion position Push the unit downwards until the Spring fully compresses pushing on Activator Cap will force the Toggle Bar into open Position Placement in Concrete Unit inserted Removal 5 ...

Страница 6: ... hole at least 1 1 2 from any edge or corner Drill a 3 4 diameter hole Drill hole in the center of core hollow Drill center of hole at least 1 1 2 from any edge or corner Always inspect a previously drilled hole make sure the hole is round and a true 3 4 diameter hole Inspect the unit for damage each time you use it If damage has occurred dispose of unit Make sure the Toggle Bar is activated in th...

Страница 7: ...s The center of the hole must be drilled at least 1 1 2 from any edge 7 Push the unit downward until the Spring fully compresses Pushing on Activator Cap will force the Toggle Bar into open position Only when the unit is activated in the open position is it safe for load bearing ...