Your GTO/PRO SW-1500 has two Limit Settings
1)
OPEN Limit setting:
(Gate in the OPEN POSITION / FACTORY SET &
NOT ADJUSTABLE)
The open limit setting is the fully open position.
2)
CLOSED Limit setting:
The CLOSED Limit setting (gate in the CLOSED POSITION)
To achieve optimum closed position, you are required to complete the
following FOUR STEPS:
Step 1
While programming, be sure the gate is in the OPEN POSITION and
the operator is mounted upside-down with “SET LIMIT" PROGRAM BUTTON visible on the control board.
Step 2
Activate your operator by pressing the entry transmitter. Your gate should now be moving from the fully open
position toward the closing position. Prepare to STOP gate when it reaches the desired closed position by pressing
the entry transmitter again. The optimum CLOSED POSITION is when the gate closes firmly, without excess
tension, against the gate post. The motor should run for one-half second after the gate closes against the gate post.
This step may be repeated until desired CLOSED POSITION is achieved. Once the desired CLOSED POSITION
has been achieved, proceed to step 3.
Step 3
With your gate firmly closed, program the closed limit setting by
PRESSING & HOLDING the “SET LIMIT" BUTTON on the control
board for 5 seconds.
Step 4
Save the setting by pressing the transmitter and allowing the gate to
return to the fully open position. YOUR CLOSED POSITION LIMIT
IS
NOW PROGRAMMED.
TESTING YOUR CLOSED LIMIT SETTING:
Press your entry transmitter and allow your gate to close. If CLOSED position
is not correct or needs to be changed you will need to CLEAR your CLOSED
LIMIT (see below) setting and follow steps 1 through 4 again.
CLEARING PROGRAMMED CLOSED LIMIT SETTING:
If you make a mistake and set the limit at the wrong position
–
press your transmitter to return the gate to its fully opened position, then press
and hold the "SET LIMIT" button for 10 seconds. This will clear the memory
for the closed limit position. Follow Steps 1-4 again.
Setting the Closed Position Limit
Fully Open Position
Fully Closed Position
1
ON
2
3
4
15
CHARGING
POWER
STATUS
RF
PULL-PUSH
MODE1
MODE2
LOCK/BEACON
OFF
120
MIN
MAX
STALL FORCE
CLOSE TIME
SET
LIMIT
LEARN
REMOTE
AUX OUT
SOLAR
PANEL
18VAC
RCVR
GRN
BLK
RED
EXI
T
SAFET
Y
EDGE
CY
CL
E
COMMON
LINK
SET LIMIT Button
ON/OFF
Turn the power switch on
the
operator
arm to the ON position
For PULL-TO-OPEN Installation