23
DIP Switches
Main DIP Switch Settings (MODES)
DIP Switch #1 - Push/Pull-to-Open
If your gate opens into the property the DIP Switch is
set to OFF (factory). If your gate opens out from the
property the DIP Switch must be set to the ON position.
NOTE: if you have a Push-to-Open gate application you
will need a Push-to-Open bracket (see Push-to-Open
Instructions on page 33).
DIP Switch #4 - Lock/Beacon
This DIP selects the mode of operation of the "AUX
OUT" terminal.
The OFF (factory) setting is selected when the GTO/
PRO Automatic Gate Lock is used with the
GTO/PRO SW 1500
. The RED wire from the lock control board is
connected to the "AUX OUT (+)" terminal and the BLACK wire from the lock control board is connected to the
"AUX OUT (–)" terninal. (OFF position provides a timed pulse of voltage to the accessory while the gate operator
is activated.)
The ON setting is selected when a beacon or light is used with the
GTO/PRO SW 1500
. One wire from the low
voltage beacon or light is connected to the "AUX OUT (+)" terminal and the other to the "AUX OUT (–)" terminal.
Wire colors do not matter for this connection. (ON position provides a continuous voltage to the accessory while
the gate operator is activated.)
CONTROL BOARD SETTINGS
1
ON
2
3
4
15
CHARGING
POWER
STATUS
RF
PULL-PUSH
MODE1
MODE2
LOCK/BEACON
OFF
120
MIN
MAX
STALL FORCE
CLOSE TIME
SET
LIMIT
LEARN
REMOTE
AUX OUT
SOLAR
PANEL
18VAC
RCVR
GRN
BLK
RED
EXIT
SAFETY
EDGE
CY
CLE
COMMON
LINK
1
ON
2
3
4
PULL-PUSH
MODE1
MODE2
LOCK/BEACON
Connecting Solar Panel(s)
IMPORTANT:
Never connect the transformer and a solar panel to the operator control board at the same time. It will
damage the control board.
If you are using the transformer included with the
GTO/PRO SW 1500
to charge the operator battery, skip this section
and go to "CONTROL BOARD SETTINGS" below.
Strip
3
/
16
" off the ends of the low voltage wire from the solar
panel and twist tightly. Attach
the RED solar panel wire
to the
SOLAR terminal
marked
(+)
and the BLACK solar panel
wire
to the
SOLAR terminal
marked
(–)
.
Tighten set screws against exposed end of wires. A dab of
household petroleum jelly on each terminal will help prevent
corrosion.
NOTE:
For multiple panels wire the panels in parallel as shown
in this diagram.
1
ON
2
3
4
15
CHARGING
POWER
STATUS
RF
PULL-PUSH
MODE1
MODE2
LOCK/BEACON
OFF
120
MIN
MAX
STALL FORCE
CLOSE TIME
SET
LIMIT
LEARN
REMOTE
AUX
OUT
SOLAR
PANEL
18VAC
RCVR
GRN
BL
K
RED
EXIT
SAFET
Y
EDGE
CY
CL
E
COMMO
N
LINK
Low Voltage Wire
from Solar Panel(s)
RED
RED
BLACK
BLACK
attach BLACK to negative (–) solar terminal on control board
attach RED to positive (+) solar terminal on control board
Solar Panels connect in PARALLEL