Step 3
Lay the measured length of low voltage wire in a trench following a path from
the selected electrical outlet to the control box. Wires coming up from the
ground should be run through PVC conduit to protect them from lawn mower
blades, weed eaters, and grazing animals. Be sure to bury the wire laid in the
trench.
Step 4
Feed the low voltage wires upward through the strain relief opening on the
lower left of the control box. Pull 6" to 8" of wire into the control box and
tighten the strain relief screw to secure the wires.
IMPORTANT INFORMATION ABOUT LOW VOLTAGE WIRE
The only wire acceptable for use with GTO products is 16 gauge multi-stranded, low voltage, PVC
sheathed wire. This particular gauge enables the transformer to provide an adequate charge through the
control board to the battery at distances up to 1000 ft.
DO NOT
use telephone wire or solid core wire. Unlike multi-stranded wire, these types of wire are
inadequate for use with your gate opener system. Telephone wire and solid core wire do not deliver
enough voltage for your gate opener to function and will cause the system to go into a condition known
as "low voltage lockout."
NEVER
splice wires together. Splicing permits corrosion and seriously degrades the wire's ability to
carry an adequate current.
Step 5
Strip
3
/
16
" off the ends of the low voltage wire
and twist tightly. Attach these ends to the
18VAC
terminals located on the
POWER IN
terminal block
(
see illustration at right
).
Be certain not to let the
exposed wires touch each other!
Insert one transformer wire into an
18VAC
terminal.
Insert the other transformer wire into the remaining
18VAC
terminal. The transformer wires can be
connected to the
18VAC
terminals regardless of color.
Tighten set screws against exposed end of wires. A
dab of household petroleum jelly on each terminal will
help prevent corrosion.
RED
BLACK
RED
BLACK
Power Cable
from First Operator
Low Voltage Wire
from AC Transformer
18VAC
SWITCH
SOLAR
RELAY OUT
SLAVE INPUTS
GRN
WHT
BLUE
BRN
ORG
RED
BLK
NC
RLY-COM
NO
MASTER INPUTS
GRN
WHT
BLUE
BRN
ORG
RED
BLK
+
–
~
~
Low Voltage Wire
from Transformer
Power Cable from
Opener Arm
PVC Pipe
WARNING! DO NOT PLUG THE TRANSFORMER
INTO AN OUTLET DURING THIS STEP! THE
TRANSFORMER MUST ONLY BE PLUGGED INTO
AN OUTLET DURING STEP 7!