23
Setting the Closed Position Limit
TURN CONTROL BOX ON
Your Mighty Mule® has two Limit Settings
1)
OPEN Limit setting:
(Gate in the OPEN POSITION / the limit is FACTORY SET and NOT ADJUSTABLE) The open
limit setting is the fully open position.
2)
CLOSED Limit setting:
(Gate in the CLOSED POSITION) To achieve optimum closed position, you are required
to complete the following FOUR STEPS:
Step 1
Confi rm that the power switch is in the ON position and the gate is in the OPEN POSITION.
Step 2
Activate your opener by pressing the entry transmitter button. Your gate should now be moving from the fully open position
toward the closed position. Prepare to STOP the gate by
pressing the entry transmitter button again when the gate
reaches the desired closed position. This step may be repeated
until desired close position is achieved. Once the desired
CLOSED position has been achieved, proceed to step 3.
Step 3
With the gate in the desired closed position PRESS & HOLD
the “SET LIMIT" button on the control board for 5 seconds.
Step 4
Press the transmitter button and allow the gate to return to the
fully open position. YOUR GATE’S CLOSED POSITION
LIMIT IS NOW PROGRAMMED.
TESTING YOUR CLOSED LIMIT SETTING:
Press your entry transmitter and allow your gate to close. If the CLOSED position is not correct or needs to be changed, you
will need to CLEAR your CLOSED LIMIT settings and follow Steps 1-4 again.
CLEARING THE PROGRAMMED CLOSED LIMIT SETTING:
If you make a mistake and set the limit at the wrong position – press your transmitter to return the gate to the fully opened
position, then press and hold the "SET LIMIT" button for 10 seconds. This will clear the memory for the closed limit
position. Follow Steps 1-4 again.
1
ON
2
3
4
5
6
7
RECEIVER
SET
LIMIT
LEARN
TRANSMIT
TER
MODES
ON
OFF
1
2
3
4
5
6
7
COM
CYCLE
CLOSE
SAFETY
EXIT/
OPEN
SHADOW
LOOP
CLOSE
EDGE
OPEN
EDGE
BLK
GRN
RED
Set Limit Button
ST
ALL FORCE
MIN
MAX