22
1
ON
2 3 4 5 6 7
ON
OFF
1 2 3 4 5 6 7
DIP#6 DIP#7 Delay Time for Auto-Close
ON
ON
15 seconds
ON
OFF
30 seconds
OFF
ON
60 seconds
OFF* OFF* 120 seconds (factory preset)
DIP#5
ON
D1 mode, constant pressure to operate gate.
OFF* B2 mode, momentary contact to operate gate.
DIP#4
ON
Push-to-open operation.
OFF* Pull-to-open operation.
DIP#3
ON
Auto-close enabled.
OFF* Auto-close disabled.
DIP#2
ON*
Buzzer warning enabled.
OFF
Buzzer warning disabled
(for auto-close and soft start/stop only).
DIP#1
ON*
Soft start enabled.
OFF
Soft start disabled.
* Factory preset.
DIP Switches
Main DIP Switch Settings (MODES)
DIP Switch #1 - Soft Start/Stop
The Soft Start/Stop feature slowly starts the
gate as it begins to open and slows the gate as
it comes to the closed position. This saves wear
and tear on the gate and gate opener system.
DIP Switch #2 - Warning Buzzer
The Warning Buzzer alerts you when the gate
opener is beginning to either open or close
the gate. It sounds for the fi rst 2 seconds in
each direction. It also sounds a warning when
the gate obstructs two times in one cycle.
Switching this to OFF only disables the open
and close warning not the obstruction warning.
DIP Switch #3 - Auto-Close
With the Auto-Close switch in the OFF position
the gate will remain open until it receives
another signal from an activation device such
as a transmitter, keypad, or push button control.
With the Auto-Close switch in the ON position
the gate opener will automatically close the
gate. The time the gate will remain open is
determined using DIP Switches #6 and #7.
DIP Switch #4 - Push/Pull-to-Open
If your gate opens into the property the DIP
Switch is set to the OFF position (factory
setting). If your gate opens out from the
property the DIP Switch must be set to the ON
position. NOTE: if you have a Push-to-Open
gate application you will need a Push-to-Open
bracket (see Push-to-Open Instructions on page
30).
DIP Switch #5 - B2/D1 Mode
This DIP Switch must remain in the OFF
position unless the gate opener is going to be
used by a guard or gate attendant, who can only
open the gate when constant pressure is applied
to a push button control device.
DIP Switches #6 and #7
The combination of these two switches
determines the amount of time the gate will
remain open when DIP Switch #3 is set to the
ON position.
CONTROL BOARD SETTINGS
IMPORTANT CONTROL BOARD SETTINGS:
CONTROL BOARD DIP SWITCH #1 is factory
preset in the ON position and MUST remain in the
ON position. Changing this setting can damage
your gate, gate opener and
possibly void your warranty!