32
M i g h t y M u l e 3 5 2
1 AUX OUT (+):
(Typically for use with automatic gate lock or light)
• Provides 12Vdc power @ a maximum of 2 Amps or less than 25 watts when the gate is in motion.
2 AUX OUT (-):
(Typically for use with automatic gate lock or light)
• Provides 12Vdc power @ a maximum of 2 Amps or less than 25 watts when the gate is in motion.
3 SOLAR PANEL (-)
•
Input for 18-22Vdc charge power from solar panel
4
18 VAC
• Input for 18-22Vac charge power from transformer
5 SOLAR PANEL (+):
•
Input for 18-22Vdc charge power from solar panel
• Input for 18-22Vac charge power from transformer.
6 EXIT:
(Typically for use with exit loop or wand)
• Activation of this input will open the gate if it’s not already at
the open position
• Activation of this input while at open limit will restart the auto
close time (if enabled).
7 SAFETY:
(Typically for use with photo beam device, loop
detector or other non-contact sensors)
• Activation of this input while the gate is closing will cause
the gate to stop and return to the opened position.
• Activation of this input while the gate is opening has no effect
(gate will continue to open).
• Activation of this input while gate is idle will prevent gate from
closing.
8 EDGE:
(Typically for use with safety edge device or other
contact sensor)
• Activation of this input while the gate is operating will cause the
gate to stop and reverse direction for approximately 2 seconds.
• Activation of this input while gate is idle will prevent gate
from opening or closing.
9 CYCLE:
(Typically for use with doorbell button or hardwired keypad)
• Each activation at this input will cycle the operation as follows:
….→ OPEN → STOP → CLOSE → STOP → OPEN → …
10 COM:
Circuit common (reference for all logic input)
• Two (2) terminals to provide extra common connection point.
3
1
6
4
5
7
8
9
10
1
ON
2
3
4
15
CHARGING
POWER
RF
PULL
-PUSH
MODE1
MODE2
LOCK/BEACON
OFF
120
MIN
MAX
ST
ALL FORCE
CL
OSE TIME
SET
LIMIT
LEARN
REMOTE
AUX
OUT
SOLAR
PANEL
18V
AC
RCVR
GRN
BLK
RED
EXIT
SAFETY
EDGE
CYCLE
COMMON
LINK
2
Control Board Connections
LOCK OUTPUTS
CHARGE POWER INPUTS
ACCES
SORY INPUTS
NOTE:
• All control inputs are dry-contact, normally open, inputs. DO NOT apply external voltage sources to these inputs.
• All inputs are connected with respect to
COMMON
terminal.
• The status light will blink once when its corresponding input is activated.