background image

IMPORTANT SAFETY INSTRUCTIONS

M i g h t y   M u l e   3 5 2  

 

 

 

                       

7

Warning signs (4 enclosed) to be installed on each side
of the gate (3–5 feet above the bottom of the gate).

This label is located

under rear mount on the opener.

Logo and warning labels (2) installed on each side of
opener housing.

1-800-543-GA

TE (4283) • www

.mightymule.com 

1.  KEEP CLEAR! Gate may move at any time. 

2.  Do not allow children to operate gate or play in gate area. 

3.  This gate is for vehicles only. Pedestrians must use separate entrance. 

Can Cause Injury or Death 

MOVING  

GATE! 

® 

E-Z GATE  OPENER 

UL325 SERIES 

® 

352

TO MANUALLY OPEN AND CLOSE THE GATE 

1.  Turn opener power switch OFF. 
2.  Disconnect front or rear mount from 

mounting bracket. 

3.  Pull opener away from mounting bracket 

and move gate. 

 

Disconnect opener ONLY when the power 

switch is OFF and the gate is not moving. 

Maximum Gate: 550 lbs. (249.4 kg); 16 ft. (4.9 m) • V

oltage: 12 Vdc; Frequency: 0Hz; P

ower: 25W • Class I, II, and III 

Vehicular Swing Gate Operator 

GTO DC SWING Series 

Conforms to UL325 

5th Edition Standards

Serial No.

MM350DUAL-0000000

05/14/08

GTO, Inc. - Tallahassee, Florida USA 

Product identification label

These warning labels should be 
found at the locations specified 
below.  If any of them are 
missing, immediately contact 
GTO for replacements. 

Содержание Mighty Mule 352

Страница 1: ...ract tort or any other legal theory during the course of the warranty or at any time thereafter The installer and or user agree to assume responsibility for all liability and use of this product relea...

Страница 2: ...s intended for use with vehicular swing gates The opener can be used in Class I Class II and Class III applications FOR YOUR RECORDS Please record the product serial number located on the rear of open...

Страница 3: ...page 19 Attaching Master Battery and Communication Cables page 20 Attaching Second Battery and Communication Cables page 21 Powering Options Transformer or Solar page 22 Connecting the Battery page 2...

Страница 4: ...ads solar panels push buttons automatic gate locks and other access control products These optional accessories see the enclosed Mighty Mule Accessory Catalog are available at most stores Your store s...

Страница 5: ...mage to the opener or its components serious injury or death Because GTO automatic gate openers are only part of the total gate operating system it is the responsibility of the consumer to ensure that...

Страница 6: ...or the type and size of gate its frequency of use and the proper class rating 2 Make sure the gate has been properly installed and swings freely in both directions Repair or replace all worn or damage...

Страница 7: ...as access to it 2 Be careful with moving parts and avoid close proximity to areas where fingers or hands could be pinched 3 Devices such as contact sensors safety edges and non contact sensors photo b...

Страница 8: ...Clean the push pull tube with a soft dry cloth and apply silicone spray to it at least once per month Grease hinges spray push pull tube with high quality silicone spray 7 To operate this equipment sa...

Страница 9: ...352 utilizes Type A an inherent i e built in entrapment sensing system as the primary type of entrapment protection Also the Mighty Mule has provisions for the connection of Type B2 protection to be u...

Страница 10: ...of automatic gate operation and are required when installing the Mighty Mule 352 E Z Gate Opener Furthermore a walk through gate must be installed if pedestrian traffic is expected near the vehicular...

Страница 11: ...NG GATE E Z GATE OPENER UL325 SERIES 352 TO MANUALLY OPEN AND CLOSE THE GATE 1 Turn opener power switch OFF 2 Disconnect front or rear mount from mounting bracket 3 Pull opener away from mounting brac...

Страница 12: ...Pivot Bracket 2 3 8 Bushings 4 32 Communication Cable 1 Gate Bracket 2 Post Bracket 4 Closed Position Stop Plate 1 2 Mounting Screw 5 Installation Video 1 Customer Support Card 1 Transformer 1 Warnin...

Страница 13: ...y from AC power source you will need to use at least one Mighty Mule 10 watt Solar Panel FM123 to charge the 12 Volt automotive or marine type battery not included See the Accessory Catalog If your fe...

Страница 14: ...pull tube fully retracted is 371 4 mounting point to mounting point Max stroke 19 Adjustable auto close timer OFF to 120 s and obstruction sensitivity Power terminal bock accommodates a transformer or...

Страница 15: ...ed dual gate system run in PVC conduit You will need to trench across the driveway in order to lay conduit for the second battery harness and communication cable 120 Volt indoor Transformer surge prot...

Страница 16: ...washer not supplied between the nuts and the fence post to prevent the thrust of the opener from pulling the bolts and washers out of the wood NOTE A fence post smaller than 6 in diameter or 6 square...

Страница 17: ...he nut because the post pivot bracket will have to be adjusted later Step 4 Attach post bracket assembly and gate bracket to the opener with the clevis pins and bushings Secure the clevis pins with ha...

Страница 18: ...6 x 1 3 4 bolt and readjust the pivot bracket until you can achieve these important clearances With the post pivot bracket in the optimum position for clearance and freedom of movement reattach the op...

Страница 19: ...ger than 8 not supplied must be used Step 10 Mark reference points for bolt holes on the gate cross member through middle of gate bracket slots Drill 3 8 holes into the gate cross member as marked Mou...

Страница 20: ...the second opener proceed to Installing the Positive Stops 1Z aSR aWbW Ab ZObSa 5ObS 6W US 0 BB3 G 0 F 5ObS 6W US BVS UObS ZSOT QO S c b Of bW OZ 5 c R Ab PS SObV UObS BVS UObS ZSOT QO S c b Of AB3 5...

Страница 21: ...of gate U bolts for tube or chain link screw or bolts for wood or metal not supplied attach the closed position stop plate horizontally about mid height on the MASTER gate frame Do not tighten it comp...

Страница 22: ...ion Ground Stop Post Check List The gate is plumb level and swings smoothly on its hinges A plate or support was added for the gate bracket if necessary The openers are level and mounted on the center...

Страница 23: ...uidelines for PVC installation and running wire DON T use too many curves in PVC Use sweeping 90 angles Wire should be easily removeable if needed DON T splice wire This can cause a voltage drop and c...

Страница 24: ...conduit from the Second Opener to the LINK terminal on the master opener arm control board Be sure to leave enough slack in the cable to accomodate routing of cable through access panel Step 4 Run the...

Страница 25: ...terminal on the second opener arm control board Be sure to leave enough slack in the cable to accomodate routing of cable through access panel Step 3 Run the end of the Second Battery Harness Cable u...

Страница 26: ...et a weatherproof cover or housing available at local electrical supply stores must be used If your gate is more than 1000 ft from an ac power source you will need to use at least one 10 watt Solar Pa...

Страница 27: ...munication Cable RED to POSITIVE Attach the 10 foot battery harness wires provided to the terminals of the battery Take care to attach the BLACK wire to the NEGATIVE terminal and the RED wire to the P...

Страница 28: ...TION ABOUT LOW VOLTAGE WIRE The only wire acceptable for use with GTO products is 16 gauge multi stranded low voltage PVC sheathed wire This particular gauge enables the transformer to provide an adeq...

Страница 29: ...before attaching it to the transformer Make sure the exposed wires do not touch each other AC 53 B31B Transformer Step 3 Strip 3 16 off the ends of the low voltage wire and twist tightly Insert these...

Страница 30: ...er SECOND closes 1st MASTER closes 8 seconds later ON ON MASTER and SECOND simultaneously open and close 1 ON 2 3 4 15 CHARGING POWER RF PULL PUSH MODE1 MODE2 LOCK BEACON AUX OUT SOLAR PANEL 18VAC RCV...

Страница 31: ...tentiometer on the con trol board operates like a volume control on a radio It controls the obstruction sensitivity or the amount of force the opener will apply to an obstruction before it automatical...

Страница 32: ...le or store it in the control box DO NOT run cable in conduit containing ac wiring The receiver range can vary from 50 to 100 feet depending upon weather topography and external interference NOTE Do n...

Страница 33: ...trol board Step 2 Activate your opener by pressing the entry transmitter Your gates should now be moving from the fully open position toward the closing position Press the transmitter again to stop th...

Страница 34: ...ck of the transmitter use a small phillips head screw driver to remove the two screws on the sides of the visor clip and separate the front cover from the transmitter With the front cover removed the...

Страница 35: ...fety devices we do not endorse any specific brand names Only use products that are certified and listed to be in compliance with any applicable UL standards Underwriters Laboratories and national and...

Страница 36: ...position Activation of this input while the gate is opening has no effect gate will continue to open Activation of this input while gate is idle will prevent gate from closing 8 EDGE Typically for use...

Страница 37: ...COM NC V V LOOP LOOP LOOP NOTE Connections are for typical applications There may be additional connection options for applications that are not illustrated here 8 10 10 10 10 7 10 6 Mighty Mule Keyp...

Страница 38: ...run inside the routing pins at the back of the opener and out the slot without being pinched when the control board access cover is replaced See the illustrations to the right and below Wire Slot To a...

Страница 39: ...over If you were working with the opener with the control board access facing up remove the opener arm from both mounts and remount it in the upright position control board cover facing down Failure t...

Страница 40: ...O OPEN installation the opener is installed while the gate is in the closed position f 0 Zb cb caV B S 0 OQYSb bW OZ OQQSaa g ab 0 OQYSb ab 0 OQYSb QY EOaVS Post Bracket Assembly EOaVS Step 2 After ve...

Страница 41: ...mit Step 1 Confirm that the power switch is in the ON position and the gate is in the CLOSED POSITION Step 2 Activate your opener by pressing the entry transmitter Your gates should now be moving from...

Страница 42: ...1 through 3 again CLEARING PROGRAMMED OPEN LIMIT SETTING If you make a mistake and set the limit at the wrong position press your transmitter to return the gate to its fully closed position then pres...

Страница 43: ...he battery may be extremely low 5 Learn Remote MASTER ARM ONLY When a new code is learned from the remote the alarm will sound Release the LEARN REMOTE button will turn the alarm off See Setting Your...

Страница 44: ...NLY Continuously ON Fast charging mode 1 5 Amps charging current 14 8 Vdc Blinking two blinks per second Soak charge Enter this mode after fast charging The battery is almost at full charge in this mo...

Страница 45: ...copy of your receipt for proof of purchase Write the RGA number issued to you on the outside of the package in LARGE BOLD PRINT Ship the package s freight prepaid to GTO Inc 3121 Hartsfield Road Tall...

Страница 46: ...It is recommended that you place a steel plate between the opener mounting brackets and masonry surface for additional strength B If a push to open installation is impossible due to traffic hazards te...

Страница 47: ...itter and has the same adjustable code settings Used for 2 gates or 1 gate and garage door battery is included Single Button Transmitter FM135 The Mighty Mule entry transmitter with adjustable code se...

Страница 48: ...your gate operator and your garage door operator Compatible with most garage door operators Automatic Gate Lock Pull to Open FM143 A MUST for added security Solenoid driven with a steel housing Unloc...

Отзывы: