16
Mounting the Opener
Step 11
Attach the opener to the securely bolted post bracket assembly and gate bracket using clevis pins, bushings, and hairpin
clips, or optional Pin Locks (see
Accessory Catalog
). Verify that the opener is level and adjust the post bracket assembly if
necessary.
Installation of the Closed Position Stop
The Mighty Mule® Gate Opener firmly holds the gate in the closed position using the positive stop plate. The
positive stop helps stabilize the gate leaf in the closed position. To further enhance the stability and security of
your gate, install the optional
Mighty Mule® Automatic Gate Lock
(
see
Accessory Catalog
).
Level Opener
Gate In Open Position
LEVEL horizontal cross member
Post Bracket Assembly
bolted to fence post
Clevis Pin, Bushing, and Hairpin Clip
Clevis Pin, Bushing, and Hairpin Clip
Gate Bracket bolted
to gate cross member
Fence Post
Step 12
Remove hairpin, clevis pin, and washer from front mount
and close the gate (remember to support opener). Fasten
the
closed position stop plate
to the end of the gate frame on
the
gate centerline
, but
do not
tighten it completely. Slide
the stop plate toward the fence post until they touch (
see
illustration
). Once you have moved the stop plate to the
correct position, tighten its hardware completely.
Use the appropriate hardware for your type of gate (use
U-bolts if you have a tube or chain link gate; wood or lag
screws for wood gates; etc.). This hardware is not provided.
Closed Position
Stop Plate
Closed Position Stop Plate mounted
on metal post with U-bolts.
Gate Hinge
The gate opens to 110º (max.)
Fence Post
Gate Post
TOP VIEW
SIDE VIEW