background image

38

If your Mighty Mule

®

 Gate Opener is not operating properly, please follow the steps below:

1.  First use the procedures found in the 

Maintenance & Troubleshooting Guide

 (

see page 36

). 

2.  If you are unable to solve the problem, call the 

GTO Service Department 

at (800) 543-1236, or (850) 575-4144.

  Refer to the serial number (located on the back of opener arm) and date of purchase when calling for assistance.

3.  If repair or replacement of your gate opener is necessary, the Service Department will assign a 

Return Goods    

 

Authorization (RGA) number 

to you for all warranty repairs

4.  Securely pack the component(s) authorized for return to the factory.  Write the RGA number issued to you on the outside
  of the package in 

LARGE BOLD PRINT

.  Ship the package(s) freight prepaid to:

 

GTO, Inc., 3121 Hartsfield Road, Tallahassee, Florida, USA 32303.

NOTE: Products returned to GTO without a Return Goods Authorization (RGA) number in LARGE 

BOLD PRINT on the outside of the package 

WILL NOT

 be accepted.  Also, items returned to GTO freight 

collect 

WILL NOT

 be accepted.

Repair Service  

GTO, Inc.

For sales call toll free: 

1-800-543-GATE 

(4283)

For technical service Call toll free:

1-800-543-1236

3121 Hartsfield Road 

 

Tallahassee, Florida, USA 32303 

 

(850) 575-0176 

 

Fax (850) 575-8912 

 

Web site www.mightymule.

com

®

E-Z GATE OPENERS

Fax (850) 575-8950 • Web site: www.mightymule.com 

E-Mail: [email protected]

The 

GTO, Inc. Technical  Service Department

 is open 

Monday – Friday 8:00 

A.M.

 – 5:00 

P.M.

 (Eastern Time)

Содержание Mighty Mule 350

Страница 1: ...er agree to assume responsibility for all liability and use of this product releasing GTO Inc from any and all liability If you are not in agreement with this disclaimer or do not feel capable of prop...

Страница 2: ...s intended for use with vehicular swing gates The opener can be used in Class I Class II and Class III applications FOR YOUR RECORDS Please record the product serial number located on the rear of open...

Страница 3: ...6 Installation of the Closed Position Stop page 16 Powering the System page 18 Solar Chart page 18 Connecting the Battery page 19 Detailed Wire Routing Diagram page 20 Connecting the Transformer page...

Страница 4: ...face gates have a high resistance to the wind If the wind is strong enough the opener will obstruct and stop The Mighty Mule E Z Gate Opener accommodates extra transmitters digital keypads solar panel...

Страница 5: ...pener or its components serious injury or death Because GTO automatic gate openers are only part of the total gate operating system it is the responsibility of the consumer to ensure that the total sy...

Страница 6: ...er is proper for the type and size of gate its frequency of use and the proper class rating 2 Make sure the gate has been properly installed and swings freely in both directions Repair or replace all...

Страница 7: ...careful with moving parts and avoid close proximity to areas where fingers or hands could be pinched 3 Devices such as contact sensors safety edges and non contact sensors photo beams provide additio...

Страница 8: ...loth and apply silicone spray to it at least once per month 7 Service the gate and gate opener regularly Grease hinges spray push pull tube with high quality silicon spray 8 To operate this equipment...

Страница 9: ...The Mighty Mule utilizes Type A an inherent i e built in entrapment sensing system as the primary type of entrapment protection Also the Mighty Mule has provisions for the connection of Type B2 protec...

Страница 10: ...ning signs alert people of automatic gate operation and are required when installing the Mighty Mule E Z Gate Opener Furthermore a walk through gate must be installed if pedestrian traffic is expected...

Страница 11: ...Death MOVING GATE E Z GATE OPENER UL325 SERIES 350 TO MANUALLY OPEN AND CLOSE THE GATE 1 Turn opener power switch OFF 2 Disconnect front or rear mount from mounting bracket 3 Pull opener away from mou...

Страница 12: ...llation Video 1 Gate Bracket 1 Post Pivot Bracket 1 3 8 Bushings 2 Customer Support Card 1 Post Bracket 2 Closed Position Stop Plate 1 2 Mounting Screw 5 E Z GATE OPENER Transformer 1 10 Battery Wire...

Страница 13: ...and the Accessory Catalog If your gate is more than 1000 away from AC ac power source you will need to use at least one Mighty Mule 5 watt Solar Panel FM121 to charge the 12 Volt automotive or marine...

Страница 14: ...is 371 4 mounting point to mounting point Adjustable auto close timer OFF to 120 s and obstruction sensitivity Power terminal bock accommodates a transformer or solar panels DIP switches simplify set...

Страница 15: ...utomotive or marine type battery in weather proof housing not included Gate Bracket Single Gate Opener Fence Post Set in Concrete Run 1000 max of low voltage wire to control box from transformer wire...

Страница 16: ...upplied between the nuts and the fence post to prevent the thrust of the opener from pulling the bolts and washers out of the wood NOTE A fence post smaller than 6 in diameter or 6 square should be ma...

Страница 17: ...e the post pivot bracket will have to be adjusted later Step 4 Attach post bracket assembly and gate bracket to the opener with the clevis pins and bushings Secure the clevis pins with hairpin clips 3...

Страница 18: ...and readjust the pivot bracket until you can achieve these important clearances With the post pivot bracket in the optimum position for clearance and freedom of movement reattach the opener to the ga...

Страница 19: ...t supplied must be used Step 10 Mark reference points for bolt holes on the gate cross member through middle of gate bracket slots Drill 3 8 holes into the gate cross member as marked Mount gate brack...

Страница 20: ...st Bracket Assembly bolted to fence post Clevis Pin Bushing and Hairpin Clip Clevis Pin Bushing and Hairpin Clip Gate Bracket bolted to gate cross member Fence Post Step 12 Remove hairpin clevis pin a...

Страница 21: ...Cross Member Gate Swings Evenly and Freely Hung Firmly and Plumb Post Bracket Assembly Gate Bracket Single Gate Opener Fence Post Set in Concrete Power Cable Closed Position Positive Stop Plate Prepar...

Страница 22: ...s more than 1000 ft from an ac power source you will need to use at least one 5 watt Solar Panel to charge the battery see Accessory Catalog Refer to the Solar Panels and Gate Activity chart below The...

Страница 23: ...r mounted in the upside down position remove the Control Board Access Panel on the bottom of the opener arm Connecting the Battery ON O FF ON OF F Control Board Access Cover Control Board Battery Harn...

Страница 24: ...connector and in line fuse The wires from the battery harness receiver transformer or solar panel and any accessories that have been installed must be routed down the sides of the opener and flatly o...

Страница 25: ...GE WIRE The only wire acceptable for use with GTO products is 16 gauge multi stranded low voltage PVC sheathed wire This particular gauge enables the transformer to provide an adequate charge through...

Страница 26: ...es do not touch each other SURGE PROTECTOR Transformer Step 7 Strip 3 16 off the ends of the low voltage wire and twist tightly Insert these ends to the 18 VAC terminal block located on the control bo...

Страница 27: ...hst is connected to the AUX OUT terminal and the other to the AUX OUT terminal Wire colors doesn t matterfor this connection ON position provides a continuous voltage to the accessory while the gate o...

Страница 28: ...ed to step 3 Step 3 With your gate firmly closed Program the closed limit setting by PRESSING HOLDING the SET LIMIT BUTTON on the control board for 5 seconds Step 4 Save the setting by pressing the tr...

Страница 29: ...e obstruction sensitivity or the amount of force the opener will apply to an obstruction before it automatically stops and reverses direc tion for approximately two 2 seconds Use a small slotted screw...

Страница 30: ...se a small phillips head screw driver to remove the two screws on the sides of the visor clip and separate the front cover from the transmitter With the front cover removed the battery and the DIP swi...

Страница 31: ...t in the control box DO NOT run cable in conduit containing ac wiring The receiver range can vary from 50 to 100 feet depending upon weather topography and external interference NOTE Do not mount upsi...

Страница 32: ...the power switch to the opener is turned off before connecting safety device wiring to the terminal blocks Unplugging the transformer does not turn power to the opener OFF Contact Sensor Input Connec...

Страница 33: ...ry contact output devices such as photo beams connected to the SAFETY input terminal If not installing a non contact sensor skip to next section PLEASE NOTE Non contact sensors are not included with t...

Страница 34: ...to next section 1 ON 2 3 4 15 CHARGING POWER STATUS RF PULL PUSH MODE1 MODE2 LOCK BEACON OFF 120 MIN MAX STALL FORCE CLOSE TIME SET LIMIT LEARN REMOTE AUX OUT SOLAR PANEL 18VAC RECR GRN BLK RED EXIT...

Страница 35: ...Depending on how you want your gate to function you can use just one or all types on the same gate Make sure the power switch to the opener is turned OFF before connecting loop wiring to the Mighty Mu...

Страница 36: ...were working with the opener with the control board access facing up remove the opener arm from both mounts and remount it in the upright position control board cover facing down Failure to remount op...

Страница 37: ...in the closed position 3 8 x 2 Bolt 3 8 Nut Push To Open Bracket optional accessory Post Bracket Post Bracket 3 8 Lock Washer Post Bracket Assembly 3 8 Washer Step 2 After verifying that you have the...

Страница 38: ...configured to push the gate open Setting the Open Position Limit Step 1 Confirm that the power switch is in the ON position and the gate is in the CLOSED POSITION Step 2 Activate your opener by press...

Страница 39: ...ed to CLEAR your OPEN LIMIT settings and follow steps one 1 to four 4 again CLEARING PROGRAMMED OPEN LIMIT SETTING If you make a mistake and set the limit at the wrong position press your transmitter...

Страница 40: ...without reaching the limit Alarm will automatically shut off after 5 minutes Power cycle the unit will also shut off the alarm 5 Learn Remote When a new code is learned from the remote the alarm will...

Страница 41: ...CHARGING LED Red Continuously ON Fast charging mode 1 5 Amps charging current Blinking two blinks per second Soak charge Enter this mode after fast charging The battery is almost at full charge in thi...

Страница 42: ...factory Write the RGA number issued to you on the outside of the package in LARGE BOLD PRINT Ship the package s freight prepaid to GTO Inc 3121 Hartsfield Road Tallahassee Florida USA 32303 NOTE Prod...

Страница 43: ...toward the column It is recommended that you place a steel plate between the opener mounting brackets and masonry surface for additional strength B If a push to open installation is impossible due to...

Страница 44: ...tion number PIN codes Each code is face programmable with additional security features built in Wired installations require 16 gauge low voltage multi stranded dual conductor direct burial wire sold s...

Страница 45: ...l UL325 Mighty Mule gate opener systems Garage Door Receiver RB709 The Garage Door Receiver allows you to use the same Mighty Mule entry transmitter see Dual and Triple Transmitters to operate your ga...

Отзывы: