background image

12

 

 

rev 06.13.12

Mount Battery Box and Control Box

Step 1

 

Remove the Control box from the Battery Box by 

removing the three screws as shown.

Step 2 

Mount the Battery Box using the screws 

(provided) or another secure mounting method. 

The battery/control box must be mounted at 

least 3 feet above the ground to protect it from 

rain splash, snow, etc., and at least 3 feet 

from an AC power source to prevent electrical 

interference. 

Step 3 

Slide the battery into position with the terminals at 

the TOP (see 

Illustration B

). 

Closed Position Stop Plate mounted

on the SECOND GATE

Closed Position Stop Plate

Low Profile

Ground Stop

in Near the Center of Driveway

FACING VIEW

SIDE VIEW

Mount Vertically

Closed Position

Stop Plate

Low Profile Ground Stop

Closed Position

Stop Plate

Step 4 

Using appropriate hardware for your type of gate, attach the vertical 

closed position stop plate to the SECOND gate frame at the point 

where it will come in contact with the low profile ground stop. Do not 

tighten it completely at this time. You must slide the closed position 

stop plate toward the low profile ground stop until they touch. Once 

you have moved the stop plate to the correct position, tighten its 

hardware completely. 

Step 5

Return the gates to their open positions and 

reattach the gate openers to the gates.

1.

KEEP CLE

AR! G

ate may mo

ve at a

ny tim

e.

2.

Do not allow c

hildre

n to 

opera

te ga

te or 

play in ga

te area.

3.

This gate i

s for vehic

les on

ly. P

edest

rian

s

must us

e a s

eparate

 entra

nce.

Moving Ga

te Can

 Ca

use

Injury O

r Dea

th

WARNING

!

Control Box

Piece of Wood

for Mounting

Screw Placement Guides

Battery Box

Control Box

Illustration B

Содержание E-Z GATE

Страница 1: ...ure to follow installation and safety instructions can result in hazards developing due to improper assembly You agree to properly install this product and that if you fail to do so Gates That Open LL...

Страница 2: ...ed Access Vehicular Gate Opener Class IV A vehicular gate opener or system intended for use in a guarded industrial location or building such as an airport security area or other restricted access loc...

Страница 3: ...e 4 Tools and Materials 5 Installation Overview for Pull To Open Gates 6 Installation of the First Gate Opener 7 Install Post Bracket Assembly and Gate Bracket 8 Attach Opener Arms 10 Install the Clos...

Страница 4: ...rce for your particular application The E Z Gate Opener also has an adjustable auto close feature After the gate reaches the fully open position it can be set for OFF or to remain open from 3 to 120 s...

Страница 5: ...onditions that can result in damage to the opener or its components serious injury or death Because automatic gate openers are only part of the total gate operating system it is the responsibility of...

Страница 6: ...ype and size of gate its frequency of use and the proper class rating 2 Make sure the gate has been properly installed and swings freely in both directions Repair or replace all worn or damaged gate h...

Страница 7: ...0 10 10 10 NEVER INSTALL any control device within gray area III After Installation 1 Attach the warning signs included to each side of the gate to alert the public of auto matic gate operation It is...

Страница 8: ...pen LLC at 3121 Hartsfield Road Tallahassee Florida 32303 or by calling 1 800 543 4283 and requesting a duplicate copy One will be provided to you free of charge Required Safety Precautions for Gates...

Страница 9: ...r entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures natural landscaping or similar obstruction A wireless cont...

Страница 10: ...at any time 2 Do not allow children to operate gate or play in gate area 3 This gate is for vehicles only Pedestrians must use separate entrance Maximum Gate 300 lbs 136 1 kg 12 ft 3 7 m Voltage 12 V...

Страница 11: ...regulates charging Sleep draw is 15 mA active draw is 3 to 8 A Auto memorization of digital remote code E Z GATE RF receiver tuned to 318 MHz Opener length with push pull tube fully retracted is 26 3...

Страница 12: ...burial wire Do not run more than 1000 ft of wire Solar Panel and Gate Activity Chart The table and map illustrate the maximum number of gate cycles to expect per day in a particular area when using fr...

Страница 13: ...uld have ball bearing hinges with grease fittings The gate post should be be secured in the ground with concrete so it will minimize twist or flex when the opener is activated Make sure there is a sta...

Страница 14: ...et 2 Post Pivot Bracket 2 3 8 Bushings 2 Customer Support Card 1 Post Bracket 2 Closed Position Stop Plate 2 2 Mounting Screw 6 E Z GATE OPE NER Transformer 1 Warning Signs 4 Wire Harness 1 Battery 1...

Страница 15: ...more than 1000 away from an AC power source you will need to use at least one 10 Watt solar panel or two 5 Watt panels to charge the 12 Volt battery Page 2 PVC conduit for protecting wiring Page 6 Pu...

Страница 16: ...clearance between the gate and the opener in both the open and closed position at the same time maintaining a maximum distance of 13 from the end of the retracted opener arm to the gate bracket with...

Страница 17: ...od posts place a metal plate or washer not supplied between the nuts and the post to prevent the thrust of the opener from pulling the bolts and washers out of the wood The post pivot bracket may not...

Страница 18: ...and a 3 8 bushing Secure the clevis pin with a hairpin clip Step 4 With the gate in the fully open position and the opener arm fully retracted adjust the post bracket assembly and gate bracket until...

Страница 19: ...bracket NOTE Tighten all lock nuts on gate bracket assembly at this time TIP Turn the post pivot bracket over for more hole alignment options You can also move the entire post bracket assembly to diff...

Страница 20: ...e excess bolt length with hacksaw or bolt cutters SIDE VIEW TOP VIEW EXAMPLES Gate Bracket Mounting Examples Attach Opener Arms Step 1 Attach the opener arms to the securely bolted post bracket assemb...

Страница 21: ...ve the gates to the closed position Step 2 Using appropriate hardware for your type of gate U bolts for tube or chain link screws or bolts for wood or metal attach the closed position stop plate horiz...

Страница 22: ...ile Ground Stop Closed Position Stop Plate Step 4 Using appropriate hardware for your type of gate attach the vertical closed position stop plate to the SECOND gate frame at the point where it will co...

Страница 23: ...y Back of Control Box Battery Wire Harness with In Line Fuse Step 5 Tuck the excess battery leads into the battery box and reattach the CONTROL BOX to the BATTERY BOX Step 6 Remove the four 4 control...

Страница 24: ...burial wire This particular gauge enables the transformer to provide an adequate charge through the control board to the battery at distances up to 1000 DO NOT use telephone wire or solid core wire Un...

Страница 25: ...ends of the low voltage wire Attach these stripped ends to the transformer terminals Make sure the exposed wires do not touch each other Step 7 Plug the transformer into the electrical outlet Use of a...

Страница 26: ...ssary Control Box Step 4 With both gates in the CLOSED position press and hold the SET LIMIT button until the alarm and the red light come on Release the SET LIMIT button Step 5 Press the remote butto...

Страница 27: ...wdriver to adjust the settings to OFF or from 3 to 120 seconds NOTE Auto Close timer is disabled gate will not automatically close if gate is not at the fully open position Re attach the cover of the...

Страница 28: ...is unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment In accordance with FCC Part 15 Section 15 21 the manufacturer is not res...

Страница 29: ...ll give the opener the most efficient leverage point for operation and provides the least possible pinch area C After verifying that you have the best position for the post pivot bracket in the closed...

Страница 30: ...if neccessary C Press and HOLD the SECOND Opener OPEN button on the control board and be prepared to RELEASE the button when the gates reached the desired open position limit Use the JOG OPEN and CLO...

Страница 31: ...touch each other Step 3 Insert one solar panel wire into a 14VAC OR SOLAR terminal Insert the other solar panel wire into the remaining 14VAC OR SOLAR terminal The wires can be connected to the 14VAC...

Страница 32: ...nd Safety Devices Photo Beams Push Button Control Gate Opening Sensor Refer to Sensor manual for additional information if needed Edge Sensor Automatic Gate Lock NOTE Connections are for typical appli...

Страница 33: ...the operation as follows OPEN STOP CLOSE STOP OPEN 4 EDGE SENSOR Typically for use with contact edge sensor Activation of this input while gate is moving will cause it to reverse direction for 2 seco...

Страница 34: ...without reaching either limit Power cycle to reset the alarm Remote will not operate the gate Alarm will automatically shut off after 5 minutes gate will remain disabled until control box is restarte...

Страница 35: ...your gate opener is necessary the Service Department will assign a Return Goods Authorization RGA number to you for all warranty repairs 4 If repair or replacement of your gate opener is necessary the...

Страница 36: ...DUAL GATE OPENER FM402 and Installation Manual...

Отзывы: