DrawingBoard IV 12
Selecting a Pre-Programmed Setup
There are three pre-programmed setups available with DrawingBoard IV:
GTCO CalComp by Turning Technologies DP5 High Resolution Binary
Summagraphics MM 1201
CalComp 2000 ASCII
These setups are commonly used within software applications as required tablet formats.
They are stored in Save Areas
Default
,
2
and
3
, respectively. Check the manual that came
with your software package to see if your application requires one of these pre-
programmed setups. The
Default
setup is available when you power on the digitizer.
To select one of the other setups:
1. Turn on Configuration Mode by clicking on the
Config/Exit
key.
2. Click on the desired
Restore
key.
3. Click on the
Config/Exit
key again to exit Configuration Mode. The new
setup is activated.
The following table lists the tablet options used by the pre-programmed setups.
Default
Save 2
Save 3
Mode
Run
Track
Point
Baud Rate
9600
9600
9600
Data Bits
8
8
7
Parity
None
Odd
Even
Data Rate
125 pps
150 pps
125 pps
Resolution
1000 lpi
500 lpi
200 lpi
Output Format
Format 23
Format 30
Format 0
Emulation
GTCO TTech DP5
High Resolution
Binary
Summagraphics
MM 1201 Binary
CalComp 2000
ASCII