GT200W
PROFESSIONAL WELDER GENERATOR
12.
13.
www.gtpower.co.nz
www.gtpower.co.nz
Engine Operation
Starting the Engine
Be sure all Pre-Operation Engine Service has
been performed. Also, Read owners manual
before starting for the first time.
(See INSTALLATION section)
NOTE:
Remove all loads connected to the
AC power receptacles before starting the
gasoline engine.
FOR A “COLD” ENGINE:
1. Put the “ON/OFF” Switch
in the “ON”(I) position.
2. Open the fuel shutoff valve.
3. Place the choke lever in the “CHOKE”
position.
4. Turn key around until engine fires. Or
for manual starting pull the cord rapidly
then release tension until the engine
fires.
CAUTION:
DO NOT hold key in start position
for more than 5 seconds.
If the engine does not start, open the
choke slightly and repeat the starting
process.
5. When the engine starts, gradually open
the choke to the “RUN” position.
To open the choke fully requires an engine
warm-up period of several seconds to sev-
eral minutes, depending on the temperature.
After starting the engine, first open the choke
(toward RUN) until the engine just begins to
run smoothly. Then open the choke in small
steps, allowing the engine to accept small
changes in speed and load, until the choke is
fully open (in RUN). During engine warm-up
the equipment can be operated.
FOR A “HOT” ENGINE:
1. Open the fuel shutoff valve.
2. Place the choke lever in the
“RUN” position.
CAUTION:
Closing the choke of a hot engine will
flood the carburetor and prevent start-
ing.
3. Turn the key around to the start position
until engine starts. Or for manual
starting pull the cord rapidly then
release tension until the engine fires.
If engine fails to start, use the choke
momentarily when starting generator.
remove the appliance(s) from the generator, reset
the RCD switch and turn the appliance on again.
If this problem persists, please have an electrician
check the appliance.
NOTE: When connecting the generator to a fixed
installation or a large number of loads through a
multi box or similar, the total current leakage across
multiple loads and the power distribution system
may exceed 30AmA, which creates nuisance
tripping of the RCD.
For this reason, in most power distribution systems,
each power connection point is usually protected
by its own RCD, rather than a single RCD for the
complete system. To address this issue, it will
be required to bypass the RCD protector in the
generator control panel. Please have an electrician
check there is no earth leakage problem with
the connected load before bypassing the RCD
protection.