![GSS CozIR-Blink Скачать руководство пользователя страница 32](http://html.mh-extra.com/html/gss/cozir-blink/cozir-blink_user-manual_2275520032.webp)
USER GUIDE
Gas Sensing Solutions Ltd.
Revision 1.2, 29 March 2021
Page | 32 For regular updates, sign up at https://gassensing.co.uk
Copyright © 2021 Gas Sensing Solutions Ltd.
TERMINAL VIEW
–
UART READ
To open the terminal window for UART communications, first ensure that ‘UART Comms’ has been
selected under the
‘Communications’ menu.
Before reading from or writing to the UART interface,
press the ‘Reset’ button.
The S0 and S1 indicate that a power-cycle has occurred after selecting the Reset button
. A ‘Z’
command must be sent first in UART mode. Sending the ‘Z’ command clears the C0
2
value giving the
??? response. Once the sensor has responded with ???, standard commands may be sent to the
sensor via the terminal window.
To read a value, write the command into the dialogue box, and click ‘Send.
Examples of commands are shown above.
‘
a
’
is the returned value for the npulse setting. In this case, the value is 16.
‘
s
’
is the returned value of the altitude compensation factor. In this case, the sensor is returning the
default of 8192.
By pressing the
‘D
ebug
’ button,
a command is sent to return the sensor settings as above. This
returns information on the state of the sensor, including sensor ID (451784).