DA98E Series AC Servo Drive Unit User Manual
50
The leads U, V and W
①
of the motor are
connected incorrectly.
The leads of the power
②
cable for the encoder are
connected incorrectly.
Connect them
①
correctly.
Fault of encoder
①
.
Change the
①
servomotor.
The set detection
①
range of position
out-of-tolerance is too
small.
Increase the detection
①
range of position
out-of-tolerance.
Excessively low
①
proportional gain of
position.
Increase the gain.
①
Insufficient torque
①
.
Check the torque limit.
①
Reduce the load
②
capacity.
Replace it wi
③
th a drive
unit and motor with
higher power.
When the main
power supply
and control
cables are
connected and
command
pulses input, the
motor does not
rotate.
High command pulse
①
frequency.
Reduce the frequency.
①
Fault of circuit board
①
.
Change the servo
①
drive unit.
5
Overheating of
the motor
The alarm is
given when the
control power
supply is
switched on.
Cable breakage
①
.
Damaged temperature
②
relay inside the motor.
Check the cable.
①
Check the motor.
②
Содержание DA98E Series
Страница 1: ......
Страница 20: ...Chapter 1 Summary 11 2 Appearance of Servomotor ...
Страница 95: ...DA98E Series AC Servo Drive Unit User Manual 86 Figure 8 7 External view and installation dimensions of BS 120 ...
Страница 96: ...Chapter 8 Product of Specification 87 Figure 8 8 External view and installation dimensions of BS 200 ...
Страница 97: ...DA98E Series AC Servo Drive Unit User Manual 88 Figure 8 9 External view and installation dimensions of BS 300 ...
Страница 98: ...Chapter 8 Product of Specification 89 Figure 8 10 External view and installation dimensions of BD 80 ...