DA98E Series AC Servo Drive Unit User Manual
48
Zero error of encoder
①
Change the
①
servomotor.
②
Have the zero of the
encoder
reconfigured by
manufacturer.
The leads U, V and W
①
are connected
incorrectly.
The leads of the power
②
cable for the encoder are
connected incorrectly.
Connect them
①
correctly.
The alarm is
given when the
control power
supply is
switched on.
Fault of circuit board
①
.
Change the servo
①
Drive Unit.
The alarm is
given when the
main power
supply is
switched on.
High supply voltage
①
Abnormal waveform of
②
supply voltage.
Check the power
①
supply.
The wires connecting
①
the brake resistor are
disconnected.
Connect the wires
①
again.
2
Overvoltage of
main circuit
The alarm is
given during the
operation of the
motor.
The brake transistor is
①
damaged.
The internal brake
②
resistor is damaged.
Change the servo
①
drive unit.