3. Foundation Requirements
12
PNEG-1510
Top Dry 24', 30' and 36' Manual Batch
Inline Centrifugal Fan Pad
Placement of the Fan Pad: GSI Transitions/Fans only.
If a fan is to be installed, refer to
to determine the concrete pad size.
1. The top of this pad should be level with the top of the bin’s foundation.
2. Recommended pad thickness is 4" minimum.
3. Front of pad should be perpendicular to bin wall.
4. Pad for heater not required.
IMPORTANT: Fan pad and fan must be leveled and smooth for proper operation. Vibration problems can
result from improper fan leveling.