SERVICE

Problem

Display shows 

"LOSS OF FLAME" 

message.

Display shows 

"HOUSING HIGH

TEMPERATURE" 

message.

Display shows 

"REAR DISCHARGE WARNING"

 message.

Display shows 

"OUT OF GRAIN"

 message.

Display shows 

"PLENUM HIGH TEMPERATURE"

message.

Display shows 

"NO AIRFLOW"

 message.

Fan motor will not start.

Top auger will not start.

Possible Cause

The flame sensor has failed to detect a burner flame,
indicating that the burner has failed to light, there is a
problem with the flame sensing circuitry or the dryer is not
getting burner fuel.

The temperature high limit located on the fan/burner housing
has opened, indicating an over temperature condition has
occurred towards the rear of the fan/heater housing. (This
control is a 200

°

F limit control that must be manually reset).

The cover on the grain discharge box has opened, indicat-
ing that grain is backing up into the discharge box.

The dryer has run low on grain, and the out of grain timer
has timed out shutting the dryer down. The unload auger
will then clean out the dryer, if the unload switch is on
during continuous flow operation. Check the out of grain
timer setting, and if necessary adjust. Also, before restart-
ing, inspect load equipment for possible damage or
adjustment.

An over temperature condition has occurred inside the
dryer plenum. (This control is a 300

°

F limit which automati-

cally resets when it cools).

The air switch contacts have opened, indicating the fan
may not be turning. The air switch may need adjustment.

1. Check that the fan circuit breaker and the fan switch are

on. Also, check for defective switch or bad wiring connections.

2. If lighted switch does not light, the air switch needs

adjustment, or the bulb may be burned out.

3. Verify closing of fan motor contactor. Check voltage on

load side of contactor. See appropriate power wiring
circuit diagram for terminal numbers. Inspect contactor
for defective points or a burned out coil.

4. Inspect connections, and check voltage applied to the

motor leads in the fan heater box to determine if the
motor is defective.

5. Check capacitors on single phase motors, and replace if

defective. If motor starts slowly, check for low voltage
during starting due to excessive voltage drop in power
supply wiring.

1. Check that the top auger circuit breaker and the load

auger switch are turned on.

2. If lighted switch does not light, the output power to the

contactor is missing. Check connections, or if the bulb is
burned out.

3. Check position of the upper auger paddle switch. It

must be down to start auger.

4. Inspect for secure mounting and wiring of mercury

switch in the terminal box on the top auger paddle
switch shaft. Include check for a defective mercury switch.

5. Verify closing of the top auger contactor. Check voltage

on load side of contactor. Inspect contactor for defective
points, or a burned out coil.

6. Inspect connections, and check voltage applied to motor

leads in motor junction box to determine if motor is defective.

7. Check that the mercury switch box is in the proper position.

Содержание COMPETITOR 2000 Series

Страница 1: ...1 A N D S E R V I C E M A N U A L DRYER OPERATION 2003 2003 2003 2003 2003 GSI G R A I N C O N D I T I O N I N G S Y S T E M S PNEG 552 COMPETITOR SERIES 2000 DRYER MODELS...

Страница 2: ...2...

Страница 3: ...Adjusting The Temperature 20 Full Heat Continuous Flow Operation 21 100 Series Continuous Flow Metering Roll Settings 22 Adjusting The Moisture Control 23 Service 24 Seasonal Inspection And Service 25...

Страница 4: ...IFICATIONS TO THE PRODUCT NOT SPECIFICALLY COVERED BY THE CONTENTS OF THIS MANUAL WILL NULLIFY ANY PRODUCT WARRANTY THAT MIGHT HAVE BEEN OTHERWISE AVAILABLE THE FOREGOING WARRANTY SHALL NOT COVER PROD...

Страница 5: ...OCKAGE OF AIR PASSAGES RUNNING FANS DURING HIGH HUMID ITY COLD WEATHER CONDITIONS CAN CAUSE AIR EX HAUST OR INTAKE PORTS TO FREEZE Thank you for choosing a GSI Airstream product It is designed to give...

Страница 6: ...r is supplied to your unit Safety decals should be read and understood by all people in the grain handling area The bottom right decal should be present on the inside bin door cover of the two ring do...

Страница 7: ...7 Three decals displayed on all Airstream Dryers Belt drives chain driven meter rolls and combustible fuels must be treated as potential danger SAFETY ALERT DECALS...

Страница 8: ...12 Be certain that capacities of auxiliary conveyors are matched to dryer auger capacities 13 Clean grain is easier to dry Fine material increases resistance to airflow and requires removal of extra...

Страница 9: ...out of grain timer The dryer outside light is turned on or off here OUTSIDE LIGHT The power to the Competitor 2000 Control System is turned on or off with this switch CONTROL POWER SWITCH This switch...

Страница 10: ...ering roll potenti ometer setting and the low speed metering roll potentiometer setting depending on the control signal UNLOAD SWITCH The fan is turned on or off with this switch The on position opera...

Страница 11: ...sition Out of grain sets the length of time the dryer will run before shut ting down when the load switch is in the auto position To change the set ting of these timers follow these in structions 1 Pr...

Страница 12: ...ING GRAIN TEMPERATURES PLENUM TEMPERATURE OR TIMERS Use the mode select to decide which of the modes you want to view DRYER SAFETY CIRCUIT The Competitor Series 2000 Control System continuously checks...

Страница 13: ...the dryer if in continuous flow operation The air switch contacts have closed prior to the fan starting indicating a freewheeling blade or improper set ting of the air switch An over temperature cond...

Страница 14: ...or resistance usually about 200ohms and place one probe on terminal J7 20 and put the other probe to the metal of the dryer dryer control box There should be an open circuit between these two points L...

Страница 15: ...int the controller will lock out all other dryer func tions and the dryer will perform its safety circuit check If a fault is found the cause will be displayed on the LCD If all safeties are found saf...

Страница 16: ...to engage the air switch You will receive a no airflow message To start the dryer when it is low on grain the airflow switches must be turned off FAN SWITCH To check one speed operation place the unlo...

Страница 17: ...ard Also anytime the high pressure regu lator is adjusted the low pressure ball valve side needs to be checked fuel supply valve at the tank on an LP dryer or valve in the fuel supply line on a natura...

Страница 18: ...sly If desired the fan can be turned off during the un ton The controller will start all the dryer components in their proper order If any of the se lected switches are improperly positioned for stage...

Страница 19: ...se the grain discharge rate and counterclockwise will de crease the discharge rate 13 To control the length of the dry cycle using only the dry time set ting programmed into the system turn the moistu...

Страница 20: ...n 90 min 95 min 100 min 105 min 110 min Cool 18 min 18 min 18 min 18 min 18 min 18 min 18 min 18 min 18 min 18 min 18 min 18 min 18 min 18 min 18 min 18 min 18 min 18 min 18 min Approx Dry Time 18 min...

Страница 21: ...turned on at the tank 9 That the electric power has been turned on 10 That the main disconnect switch on the dryer is on 11 That you have wet grain in the wet holding bin 12 That you know the incoming...

Страница 22: ...LP gas models adjust the PRESSURE REGULATOR high fire on the burner fuel line so that burner will reach the thermostat setting and switch to low fire pressures may be required up to 25 lbs Natural gas...

Страница 23: ...emoval would be about 100 minutes Add 10 minutes to insure that the grain is dry 6 After the time in step 4 turn the UNLOAD to 1 SPEED and set the METER ROLL SPEED HIGH SPEED potentiometer to the sett...

Страница 24: ...ults of this adjustment 100 SERIES CONTINUOUS FLOW METERING ROLL SETTINGS Initial Moisture 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 2 Speed High 875 775 675 575 476 385 317 270 241 213...

Страница 25: ...inches 3 Grain temperatures can be monitored by pressing the mode select but ton 4 If the METERING ROLL switches to LOW and only stays on low for a minute or two and switches back to HIGH speed up the...

Страница 26: ...26 SERVICE...

Страница 27: ...Note If on site bearing relubrication is to be performed see lubrication instructions for ball bearing motors To keep motor bearings properly lubricated and dispel any accumu lation of moisture withi...

Страница 28: ...indication of stick ing or binding 6 Inspect the top auger and bot tom auger drive lines for proper adjustment and condition Re adjust line tension as required Note All of the auger and metering roll...

Страница 29: ...ellor free from the bushing a wheel can be used to pull the bushing off of the motorshaft Reattachbushingonto propellortopreventthelossofparts Note During manufacture the propellor and bushing on the...

Страница 30: ...einstall conduit and wires through hole in fan heater hous ing and carefully connect all electrical wiring 7 Adjust position of motor by tem porarily mounting fan blade on motor shaft Rotate fan blade...

Страница 31: ...alve stem and body Do not energize the coil when it is removed as the coil may be come damaged due to exces sive current flow 3 Regulator and gas solenoid valve s The gas regulator and solenoid valve...

Страница 32: ...mum discharge rate 999 the metering roll speed should be 17 5 RPM 2 DC electric motor The direct current DC motor provides the drive for the metering roll and is located on the front left hand side of...

Страница 33: ...he metering roll This per mits opening of the metering roll access door For service or inspection with out unloading the dryer and prior to using the service tool the plenum bot tom closure panel and...

Страница 34: ...34 SERVICE 100 SERIES SINGLE FAN WIRING TO CONTROL BOX...

Страница 35: ...35 SERVICE 100 SERIES FRONT PANEL EXTERNAL WIRING...

Страница 36: ...36 SERVICE 100 SERIES FRONT PANEL INTERNAL WIRING...

Страница 37: ...37 SERVICE 100 SERIES LOWER BACK PANEL COMPONENT LAYOUT...

Страница 38: ...38 100 SERIES EXTERNAL WIRING TO DRYER SERVICE...

Страница 39: ...39 100 SERIES UPPER CONTROL BOX WIRING SERVICE...

Страница 40: ...40 SERVICE 100 SERIES MAIN POWER WIRING...

Страница 41: ...41 SERVICE 100 SERIES CONTROL SCHEMATIC...

Страница 42: ...42 SERVICE 100 SERIES CONTROL SCHEMATIC...

Страница 43: ...43 SERVICE 100 SERIES CONTROL SCHEMATIC...

Страница 44: ...44 SERVICE 100 SERIES 220VOLT 1 PHASE POWER SCHEMATIC...

Страница 45: ...45 SERVICE 100 SERIES 220VAC 3PHASE POWER SCHEMATIC...

Страница 46: ...46 SERVICE 100 SERIES 440VAC 3 PHASE POWER SCHEMATIC...

Страница 47: ...show the date and time if this has occured once power has returned 2 Display not finished initial setup The monitor will display a copyright message and model number total running time in hours and mi...

Страница 48: ...ndicating the fan may not be turning The air switch may need adjustment 1 Check that the fan circuit breaker and the fan switch are on Also check for defective switch or bad wiring connections 2 If li...

Страница 49: ...Avoid leaving the dryer columns full for long periods at a time 2 3 days while not operating the dryer or during rainy weather 3 Empty the dryer Keep the dryer clean Do not allow fine material to gat...

Страница 50: ...eading on the thermometer Replace control assembly if it cannot be set to cause its switch to go to the open circuit position with normally hot air plenum temperatures 3 If the burner continues to ope...

Страница 51: ..._____________________________________________________ ___________________________________________________________________________________________________ ______________________________________________...

Страница 52: ...52...

Страница 53: ...53 GSI G R A I N C O N D I T I O N I N G S Y S T E M S 1004 E Illinois St Box 20 Assumption IL 62510 0020 phone 217 226 4421 fax 217 226 4420 August 2003...

Отзывы: