
2000 Autoflow
34
ELECTRICAL POWER SUPPLY
Conduit Runs
Control Wires
Run #1
Autoflow Control Box to Master
Fan/Heater Control Box
Five (5)-Control wires 16ga minimum
(NOTE: A shielded two conductor 16ga cable should
be used for the network connections.)
Run #2
Autoflow Control Box to Actuator
Control Box
Five (5)-Control wires 16ga minimum
Run #3
Autoflow Control Box to Wet
Supply Rotary Switch
Four (4)-Control wires 16ga minimum
Run #4
Autoflow Control Box to Storage
Chamber Rotary Switch
Five (5)-Control wires 16ga minimum
Run #5
Autoflow Control Box to Drying
Chamber Rotary Switches
Six (6)-Control wires 16ga minimum
Run #6
Autoflow Control Box to Fill
SystemControl Box (if applicable)
Eleven (11)-Control wires 16ga min.
Run #7
Master Fan/Heater Control Box to
Slave Fan/Heater Control Box
Four (4)-Control wires 16ga minimum
(NOTE: A shielded two conductor 16ga cable should
be used for the network connections.)
Run #8
Slave Fan/Heater #1 Control Box
to
Slave Fan/Heater #2
Control Box
Four (4)-Control wires 16ga minimum
(NOTE: A shielded two conductor 16ga cable should
be used for the network connections.)
Power/Motor Wires
Run #1
Entrance Panel to Master Fan/
Heater Control Box (for fan
motor)
Run #2
Entrance Panel to Slave Fan/
Heater Control Boxes (if
applicable, for fan motor)
Run #3
Entrance Panel to Fill System
Control Box ( if
applicable)
-For Fill System #1 motor starter
-For Fill System #2 motor starter
(if applicable)
-For Aeration fan motor starter
Run #4
Fill System Control Box to Fill
System #1 Motor
Run #5
Fill System Control Box to Fill
System #2 Motor ( if
applicable)
Run #6
Fill System Control Box to
Aeration Fan Motor
Run #7
Entrance Panel to Actuator
Control Box
-110V AC, 110V N, Ground wire
for battery charger
Grounding
All Control Boxes should be properly
grounded with a ground lug mounted in each control
box.
Содержание Autoflow 2000 Series
Страница 9: ...2000 Autoflow 9 Component Placement INSTALLATION...
Страница 17: ...2000 Autoflow 17 INSTALLATION Close Up Detail of Grain Temperture Sensor Wiring...
Страница 19: ...2000 Autoflow 19 Plenum hi limit installation INSTALLATION...
Страница 22: ...2000 Autoflow 22 INSTALLATION Figure 6...
Страница 24: ...2000 Autoflow 24 INSTALLATION Figure 7...
Страница 27: ...2000 Autoflow 27 INSTALLATION Figure 9...
Страница 29: ...2000 Autoflow 29 INSTALLATION Figure 10 3 00 ROOF MOUNT PLATE COMPRESSION COUPLER...
Страница 31: ...2000 Autoflow 31 INSTALLATION Figure 11...
Страница 39: ...2000 Autoflow 39 ELECTRICAL POWER SUPPLY Figure 18...
Страница 45: ...2000 Autoflow 45 Figure 23 ELECTRIAL POWER SUPPLY...
Страница 47: ...2000 Autoflow 47 ELECTRICAL POWER SUPPLY Autoflow to Ground Interconnect Figure 25...
Страница 52: ...2000 Autoflow 52 ELECTRICAL POWER SUPPLY Figure 29...
Страница 54: ...2000 Autoflow 54...