Installation Diagrams

To release Security Caps push a
screwdriver into slots on the side

and pull forward.

Door Control is mounted to electrical pattress box using security
screws provided. Both Security Caps are

then clipped onto Door Control.

Flush Mounting

To attach Security Caps: Simply
align the tabs into holes and push

on until click is heard.

4

Installation Diagrams

When Surface Mounting the Door Control

a Surface Mount Collar is required.

- Fix Surface Mount Collar to

wall, ensure arrow is

pointing upwards

After fixing Surface Mount Collar to wall
(as above) and wiring is complete as per

wiring diagrams on pages 6-11, the Door
Control may then be screwed to

Surface Mount Collar using
security screws provided.
Both Security Caps are

then clipped onto the Door
Control.

To attach Security Caps: Simply
align the tabs into holes and push

on until click is heard.

Surface Mounting

Security Caps

Содержание Wi-Smart

Страница 1: ...uilding GSD Digital Keypad GSD Proximity Switch GSD Pin Prox Switch GSD Biometric Switch Features 50 users Access control Door Monitoring Manager User Fire and Intruder alarm interface Backlighting Ta...

Страница 2: ...Door Control 2 Replace the default link The LED will turn amber after 5 secs Remove the link immediately to default the Door Control 3 Initial Setup Restoring Factory Settings Wi Smart only Step Desc...

Страница 3: ...d 4 Installation Diagrams When Surface Mounting the Door Control a Surface Mount Collar is required Fix Surface Mount Collar to wall ensure arrow is pointing upwards After fixing Surface Mount Collar...

Страница 4: ...cross A B at the Controller and on the last Door in the daisy chain 12V 0V NO COM NC IP1 IP2 IP3 IP4 OP1 OP2 A B TAMP TAMP 1 2 3 4 5 6 Arm Alarm Input Arm Output N O IP3 OP1 7 Wiring Diagrams 12V Wiri...

Страница 5: ...n the diagram are connected to OV of the Door Control 0V 0V OP1 Data0 Data IP3 Data1 Clock IP4 Fire Alarm IP2 Door Contact IP1 Door Exit Button OP2 Alarm Sounder 12V DC Only 0V BreakGlass Unit Max Dat...

Страница 6: ...P2 A B TAMP TAMP 1 2 3 4 5 6 IP3 Card and Pin Card or Pin Lock Door selectable from Doors tab in PC Application 10 Wiring Diagrams 12V Wiring Diagram with Interlock Connection 12V Linear Power supply...

Страница 7: ...ntrols that don t have an address start to beep out the next available address 2 Hit any key on the beeping Door Control to assign this address or present a Card on the beeping Proximity unit to assig...

Страница 8: ...MP TAMP 1 2 3 4 5 6 Wi Smart Slave Reader Common the OV from the Slave Reader and the OV from the Door Control to avoid any ground loop issues Note Do not mount on metal surfaces 12V DC Only 0V Max Da...

Отзывы: