background image

2

Initial Setup

Power Supply

                      

12V DC

Current consumption    

70mA

Current consumption with load (max)

100mA

Relay Contact Rating

5 Amps /240V ac

Operating Temperature

-20  C   to +60  C

Moisture Resistance   

IP 67

Dimensions  - Flush Mount

 

W.

 87mm 

D. 

21mm 

H.

 119mm

                     - Surface Mount                        

W.

 87mm 

D. 

35mm 

H.

 119mm

Number of Users 

20000

       

 

Technical Specs

Initial Installation

The Door Control should be Factory Defaulted after installation. This will restore all
default settings to the Door Control and will unenrol it from any existing GSD
Controller.
The Door Control will then start to scan and enrol on a GSD controller.

Refer to the section ‘Enrolling Door Controls’ on page 12 for instructions on how to
configure the GSD Windows Software.

Restoring Factory Settings:
Wi-Smart Pin

 Step             Description

    

   1         Remove default link on back of the Door Control.

   2

Replace the default link. The LED will turn amber after 5 secs, Remove

                             the link immediately to default the Door Control.
                             

3

     Initial Setup

Restoring Factory Settings:
Wi-Smart only

 Step             Description

    

   1         Present Programming Card 2 Times

   2

Present Any Card Once

                             

Programming

Card x 2

AnyCard

x 1

Adding a Programming Card

Note: Add a progrmming card to the Door Control. The Door Control must
be disabled first if it has been enrolled onto a GSD Network Controller.
Follow the method below to add a programming card to the Door Control.

Adding a Programming Card

AnyCard

 x 2

 Step             Description

    

   1         Remove security caps and power down unit.

   

Power up unit and Present Any Card 2 times

   2

immediately. This card is now the Programming
Card for the unit. Refit security caps                             

Factory Default PIN codes

The following PIN codes are the Factory Default Settings:

- The Default Engineer code is ‘6666’

- User PIN ‘1111’

Note: The User PIN ’1111’ is deactivated when the Door Control is enrolled
onto a GSD Network Controller.

Содержание Wi-Smart

Страница 1: ...uilding GSD Digital Keypad GSD Proximity Switch GSD Pin Prox Switch GSD Biometric Switch Features 50 users Access control Door Monitoring Manager User Fire and Intruder alarm interface Backlighting Ta...

Страница 2: ...Door Control 2 Replace the default link The LED will turn amber after 5 secs Remove the link immediately to default the Door Control 3 Initial Setup Restoring Factory Settings Wi Smart only Step Desc...

Страница 3: ...d 4 Installation Diagrams When Surface Mounting the Door Control a Surface Mount Collar is required Fix Surface Mount Collar to wall ensure arrow is pointing upwards After fixing Surface Mount Collar...

Страница 4: ...cross A B at the Controller and on the last Door in the daisy chain 12V 0V NO COM NC IP1 IP2 IP3 IP4 OP1 OP2 A B TAMP TAMP 1 2 3 4 5 6 Arm Alarm Input Arm Output N O IP3 OP1 7 Wiring Diagrams 12V Wiri...

Страница 5: ...n the diagram are connected to OV of the Door Control 0V 0V OP1 Data0 Data IP3 Data1 Clock IP4 Fire Alarm IP2 Door Contact IP1 Door Exit Button OP2 Alarm Sounder 12V DC Only 0V BreakGlass Unit Max Dat...

Страница 6: ...P2 A B TAMP TAMP 1 2 3 4 5 6 IP3 Card and Pin Card or Pin Lock Door selectable from Doors tab in PC Application 10 Wiring Diagrams 12V Wiring Diagram with Interlock Connection 12V Linear Power supply...

Страница 7: ...ntrols that don t have an address start to beep out the next available address 2 Hit any key on the beeping Door Control to assign this address or present a Card on the beeping Proximity unit to assig...

Страница 8: ...MP TAMP 1 2 3 4 5 6 Wi Smart Slave Reader Common the OV from the Slave Reader and the OV from the Door Control to avoid any ground loop issues Note Do not mount on metal surfaces 12V DC Only 0V Max Da...

Отзывы: