8
Wiring Diagrams
9
Wiring Diagrams
12V
Wiring Diagram with Slave Reader
12V Linear
Power supply
Door Exit Button
0V
Door Contact
0V
Common the OV from the
Fire Alarm Panel and the OV from the Door Control to
avoid any ground loop issues.
Fire Alarm
Panel
0V
When the fire alarm
is activated (0V removed from IP4) the door will
be opened
12V
Sounder
Smart Slave
(See maunal for detailed
wiring diagram)
12V
0V
NO
COM
NC
12 - 24 VAC
12 - 24 VAC
Wiring for StikeLock only using 12 - 24VAC supply
Note: All OV shown in the
diagram are connected to
OV of the Door Control.
0V
0V
OP1
Data0/Data
IP3 Data1/Clock
IP4 Fire Alarm
IP2 Door
Contact
IP1 Door Exit Button
OP2 Alarm/Sounder
12V DC
Only
0V
BreakGlass Unit
Max Data Cable
Length
-100m
Shielded
Cable
Note: Fire Alarm Override is
deactivated until the Door Control joins a network.
16V
Varistor
16V
Varistor
12V
0V
NO
COM
NC
IP1
IP2
IP3
IP4
OP1
OP2
A
B
TAMP
TAMP
485 Network Connection A & B
Common the OV from the Door
Control and the COM on the Controllers “Door Network”
when using the 485 interface.
Place a 120ohm Termination Resistor across A & B at the
Controller and on the last Door in the daisy chain.
12V
0V
NO
COM
NC
IP1
IP2
IP3
IP4
OP1
OP2
A
B
TAMP
TAMP