- Add sequence number suf
fi
x (no maximum value):
File name: imageXXXXXXX.jpg
X: Sequence Number
- Add sequence number suffix up to _ and then start over:
File Name: imageXX.jpg
X: Sequence Number
The file name suffix will end at the number being set. For example, if the setting is “10”, the file name will start
from 00, end at 10, and then start all over again.
- Overwrite:
The original image in the FTP site will be overwritten with a static filename by the new uploaded file.
Save :
After completing all the settings mentioned above, please click on the Save button to save all the settings in this
page.
9.9. Motion Detection
The Motion Detection function allows detecting suspicious motion and triggers alarms when motion volume in the
detected area reaches/exceeds the determined sensitivity threshold value.
In the Motion Detection setting page a frame (Motion Detection Window) is displayed in the Live View Pane. The
Motion Detection Window is for defining the motion detection area. To change the size of the Motion Detection
Window, move the mouse cursor to the edge of the frame and draw it outward/inward. When you move the mouse
cursor to the center of the frame and hold the click, you can shift the frame to the intended location.
Up to 10 Motion Detection Windows can be set. click on the “Add” button under the Live View Pane to add a Motion
Detection Window. To delete a Motion Detection Window, move the mouse cursor to the selected Window, and
click on the “Delete” button.