- Enable Alarm Output:
Check this item and select the predefined type of alarm output to enable alarm relay output when tampering is
detected.
- Record Stream to SD Card:
When you check this item, the alarm-triggered recording will be stored on your Micro SD/SDHC card when
tampering is detected.
The pre-trigger buffer recording function allows users to check what happened to trigger the alarm. The pre-
trigger buffer time range is from 1 to 3 seconds.
Select <Upload for __ sec> to set the recording duration after the alarm is triggered. The setting range is from 1
to 99999 seconds.
Select <Upload while trigger is active> to record the triggered video until the trigger is turned off.
NOTE: Please make sure that the local recording (with Micro SD/ SDHC card) is activated so that this function can
be implemented. See section 9.13. 'Recording (on Camera)' for further details.
- Send Alarm Message by FTP:
The Administrator can select whether to send an alarm message by FTP when tampering is detected.
- Send Alarm Message by E-Mail:
The Administrator can choose to send an alarm message by E-Mail when tampering is detected.
- Upload Image by FTP:
After selecting this item, the Administrator can assign a FTP site and configure various parameters as shown in
the figure below. When tampering is detected, event images will be uploaded to the appointed FTP site.
The <Pre-trigger buffer> recording function allows users to check what happened to trigger the alarm. The pre-
trigger buffer time range is from 1 to 20 frames.
On the other hand, the <Post-trigger buffer> is for uploading a certain amount of images after the alarm input is
triggered. The post-trigger buffer time range is from 1 to 20 frames.
Check the box <Continue image upload> to upload the triggered images during a certain time or keep uploading
until the trigger is off.
- Select <Upload for __sec> and enter the duration in the blank. The images of the duration will be uploaded to
the FTP when the alarm input is triggered. The setting range is from 1 to 9999 seconds.
- Select <Upload while trigger is active> to keep the images being uploaded to the FTP while the trigger is active,
i.e. until the alarm is stopped.
Set the Image frequency as the upload frame rate. The setting range is from 1 frame to 15 frames.