9.8. Application (Alarm Settings)
The IP Camera is equipped with one alarm input and one relay output for cooperation with the alarm system to
catch event images. Please refer to the alarm pin definition below to connect alarm devices to the IP Camera if
needed. The alarm configuration page is also shown below.
PIN 1:
PIN 2: Output-
PIN 3: Input+
PIN 4: Input-
Additional for GCI-K1503B and GCI-G0509B with RS-485 Interface:
PIN 5: GND
PIN 6: D-
PIN 7: D+
Alarm Switch :
The Administrator can enable or disable the alarm function.
Alarm Type :
Select an alarm type, “Normal close” or “Normal open”, that corresponds with the alarm application.
Alarm Output :
Define the alarm output signal as “high” or “low” for the normal alarm output status according to the current
alarm application.
46
English