7.4 Motor data
POMONA 07
• 1 x 230 V motor. 0.25 kW. IP55.
• 3 x 230/400 V motor. 0.25 kW. IP55.
POMONA 23
• 1 x 230 V motor. 1.25 kW. IP55.
• 3 x 230/400 V motor. 1.5 kW. IP55.
• 4-stroke petrol engine. 2.6 kW.
POMONA 32
• 3 x 400 V motor. 4.0 kW. IP55.
• 4-stroke diesel engine with manual start. 4.6 kW.
POMONA 42
• 3 x 400 V motor. 11.0 kW. IP55.
• 4-stroke diesel engine with electric start, including battery and
wiring. 13.1 kW.
8. Installation
8.1 Foundation
Grundfos recommends to install the pump on a concrete
foundation which is heavy enough to provide permanent and rigid
support to the entire pump. The foundation must be capable of
absorbing any vibration, normal strain or shock. As a rule of
thumb, the weight of the concrete foundation should be 1.5 times
the weight of the pump. The concrete foundation must have an
absolutely level and even surface.
The foundation should always be 200 mm longer and wider than
the pump.
Fig. 3
Minimum size of the concrete foundation
In installations where low-noise operation is particularly
important, we recommend a foundation with a weight up to five
times that of the pump.
Dimensions of base frame
8.2 Positioning
The pump should be installed in a well-ventilated, frost-free
location.
For inspection and repair, suitable clearances for pump or motor
removal must be allowed.
8.3 Aligning versions with bearing bracket
Check the equipment for transport damage. Fit the fixing bolts
loosely in the foundation and level the base frame with a spirit
level and shims. Check the alignment of pump and motor to the
coupling using a straight edge. The straight edge must be flush
with both coupling halves. Move the straight edge 90 ° and check
again.
Fig. 4
S
1
^S
2
Check that the gap between the coupling halves is the same on
the whole circumference of the coupling. Press the pump impeller
towards the pump during this process.
The dimension S
1
^S
2
between the ends of the pump and motor
shafts depends on the make of coupling. If the coupling and
motor were not supplied by Grundfos, observe the manufacturer's
instructions for the coupling.
Remove or add shims under the feet of the pump housing or
motor, if necessary.
Careful alignment significantly increases the service life of the
coupling as well as that of bearings and seals. It must be easy to
turn the coupling by hand after alignment. Refit the coupling
guard in accordance with regulations.
Note
The foundation/installation must be carried out in
accordance with the following instructions.
Non-compliance may result in functional faults which
will damage the pump components.
TM
04
60
27
47
09
Type
Description
Dimensions
[mm]
Length Width
PO07
Block version on base frame
280
195
PO23
475
230
PO32
565
285
PO07
Pump with coupling and motor
485
200
PO23
740
330
PO32
1000
450
PO42
1250
540
PO42 Pump with coupling and diesel engine
1250
540
100mm
100mm
100mm
100mm
Warning
When pumping hot liquids, make sure that persons
cannot accidentally come into contact with hot
surfaces.
Caution
In installations where low-noise operation is
particularly important, the pump must placed on its
own foundation. The foundation must be isolated
from the rest of the building to prevent the
transmission of noise as much as possible.
Coupling size
S
1
^S
2
[mm] (see fig.
)
B 68-95
2.5
B 110-140
3.5
B 160-180
4.5
T
M
03
82
92
10
07
Warning
Operation without a coupling guard is not permitted
on safety grounds.
Содержание POMONA PO07
Страница 1: ...POMONA Installation and operating instructions GRUNDFOS INSTRUCTIONS...
Страница 2: ...2...
Страница 93: ...RU 93 13 1 a b c d e f g h 2 a b c d e 3 3 a b c d e f g h i j 8 3 k...
Страница 94: ...RU 94 4 a b c d 5 a b c d e...
Страница 100: ...100...
Страница 101: ...101...
Страница 102: ...102...