background image

English (GB)

4

3.1 Applications

Grundfos Multilift MD and MLD lifting stations are designed for 
the collection and pumping of domestic wastewater with no free 
flow to sewer level. Grundfos Multilift MD and MLD lifting stations 
are designed for the collection and pumping of the following 
liquids:
• domestic wastewater, including grey wastewater without 

faeces, black wastewater with faeces (discharge from water 
closets)

• sludge-containing water.
The lifting stations are capable of pumping liquids containing 
fibres, textiles, faeces, etc., below sewer level from multi-family 
houses, offices, schools, hotels, restaurants, public areas and 
other commercial buildings and similar industrial applications. 
Do not pump rainwater with the Multilift MD and MLD lifting 
stations for these two reasons:
• The motors of the lifting stations are not designed for 

continuous operation which may be necessary in case of 
heavy rainfall.

• Rainwater must not be discharged into a lifting station inside a 

building according to EN 12056-4.

If in doubt, please contact Grundfos for advice.
Do not discharge the following substances/types of wastewater 
via a lifting station:
• solid matter, tar, high content of sand, cement, ash, cardboard, 

debris, garbage etc.

• wastewater from sanitary installations situated above the flood 

level (this must be drained away via a free-flow drainage 
system according to EN 12056-1).

• wastewater containing hazardous substances such as greasy 

wastewater from large-scale catering establishments. 
For drainage of greasy wastewater, use a grease separator 
according to EN 1825-2 between a canteen or commercial 
kitchen and the Multilift MD or MLD.

4. Transportation and storage

For long periods of storage, the LC 221 controller must be 
protected against moisture and heat. 
After a long period of storage, the pumps must be inspected 
before they are started up again. Make sure that the impellers 
can rotate freely.

5. Product description

The MD and MLD Multilift lifting stations are described in the 
following sections: 
• section 

5.1 Lifting station

 describing the lifting station with 

collecting tank, pumps, non-return valve and level sensor 

• section 

5.2 LC 221 controller

 describing the controller as well 

as the functions and operation of the controller.

In section 

7. Installation of lifting station

 and the following 

sections, the above components are described as one unit.

5.1 Lifting station

The Grundfos Multilift MD and MLD lifting stations are supplied 
complete with two single- or three-phase submersible pumps 
connected to the LC 221 controller incorporating a level sensor.

Type key, lifting station

Nameplate, lifting station

Fig. 3

Nameplate, lifting station

Warning
The motor lifting eye is only intended for lifting the 
pump. Never lift or lower the lifting station by means 
of the lifting eye.

Note

Lift the lifting station by the collecting tank.

Example

M

L

D

.22

.3

.4

Multilift lifting station
L = large tank
D = 2 pumps
Output power, P

/ 100 (W)

1 = single-phase motor 
3 = three-phase motor
2 = 2-pole motor
4 = 4-pole motor

T

M

04

 76

39

 22

10

Pos. Description

1

Type designation

2

Product number

3

Production code (year/week)

4

Frequency [Hz]

5

Number of  voltage [V]

6

Voltage [V]

7

Full-load current [A]

8

Motor input power P

1

 [kW]

9

EAC and CE mark

10

Duty type

11

Serial number

12

Maximum flow rate [m

3

/h]

13

Minimum head [m]

14

Maximum head [m]

15

Maximum liquid temperature [°C]

16

Maximum ambient temperature [°C]

17

Weight [kg]

18

European norm identification code

19

Notified Body

20

Reference number for the Declaration of Performance

Typ

Prod.-Nr.

P. c.

f

Hz

Serial no.

Phases

U

V

A

kW

G

kg

m

m

98127055

0197

I

1/1

P

1

Q

max

H

min

H

max

T

Med
max

T

Amb
max

m /h

3

C

C

Made in Germany

96075419

DK - 8850 Bjerringbro, Denmark

1

2

3

4

5

6

10

11

12

13

14

15

16

17

18

20

19

7

8

9

Содержание Multifit MD Series

Страница 1: ...Multilift MD MLD Installation and operating instructions GRUNDFOS INSTRUCTIONS Other languages http net grundfos com qr i 98127059...

Страница 2: ...clamps DN 50 for diaphragm pump connection or inlet DN 50 1 x gasket kit DN 80 4 bolts M16 nuts and washers galvanized 1 Symbols used in this document 2 2 Scope of delivery 2 2 1 MD 2 2 2 MLD 2 3 Gene...

Страница 3: ...pening 6 Vertical inlet DN 150 seal is accessory 7 Fixing point 8 Non return butterfly valve DN 80 with inspection cover and drain screw to lift up the valve flap 9 Discharge adapter flange DN 80 to p...

Страница 4: ...ong period of storage the pumps must be inspected before they are started up again Make sure that the impellers can rotate freely 5 Product description The MD and MLD Multilift lifting stations are de...

Страница 5: ...or is made of cast iron The pump has a mechanical shaft seal See more technical data in section 12 Technical data Single phase motors are protected by a thermal switch in the windings and run via a ca...

Страница 6: ...vel sensor When the first start level is reached the first pump will start and when the liquid level has been lowered to the stop level the pump will be stopped by the controller If the liquid level r...

Страница 7: ...water pipe burst an alarm will be indicated by the controller connecting a piezoresistive pressure sensor PCB pre assembled connecting an external alarm reset connecting the thermal switch of the moto...

Страница 8: ...in section 6 1 Description of display Operating buttons pos 2 The level controller is operated by the operating buttons placed under the display The functions of the operating buttons are described in...

Страница 9: ...free changeover NO NC contacts with max 250 V 2 A Attention Connect these terminals to supply network potential or low voltage but do not mix the two X11 9 Terminals for high water level alarm X10 10...

Страница 10: ...ible if the level controller detects a fault and the fault will be written into the fault log After you have entered the fault log the symbol will switch off See section 6 3 Information menu Setup The...

Страница 11: ...pump 1 The symbol is visible when pump 1 is running and flashes when pump 1 has a fault In case of fault it can be combined with other symbols or fault codes in the display Pump operation and pump fa...

Страница 12: ...sing the button Enter values or select settings from a list by means of the buttons and Save the settings by pressing the button See also fig 12 The following settings can be made start level rated cu...

Страница 13: ...enu by means of the buttons and Select the desired menu item by pressing the button See also fig 13 In the information menu the following data can be read fault indications operating hours number of s...

Страница 14: ...is functioning A leaky non return valve can allow liquid in the outlet pipe to flow back in to the collecting tank Remove any blockage from the venting system see fig 33 F012 Operating time exceeded...

Страница 15: ...button The fault indication will be reset when the fault has disappeared has been removed or the ON OFF AUTO switch has been set to OFF position You can get an overview of faults in the fault log in i...

Страница 16: ...g 15 Installation sketch Multilift MD Fig 16 Installation sketch Multilift MLD TM05 1864 3811 4 7 2 1 6 5 3 TM05 1865 3811 3 4 6 5 Pos Accessories Product number 1 Socket seal DN 100 97726942 2 Socket...

Страница 17: ...ves accessory must be placed outside the building If the wastewater is discharged into a collecting line this collecting line must have a filling ratio of at least h d 0 7 The collecting line must be...

Страница 18: ...et pipe and lifting station to avoid inflow during maintenance and service We recommend an easy to handle PVC isolating valve Fig 22 Installation of isolating valve TM05 0336 1011 Caution Multilift MD...

Страница 19: ...n the discharge side To facilitate servicing of the diaphragm pump we recommend fitting a 1 1 2 isolating valve to the tank port 4 Fix the tank to the floor Fig 25 Fixing point for fixation of tank to...

Страница 20: ...ts for lifting stations except on a houseboat or pontoon boat The preset value is 0 Alarm delay High temporary inflow can cause short time high level alarm This situation may arise when a backwash fil...

Страница 21: ...diagram three phase Multilift MD MLD 12 3 4 and MD MLD 15 3 4 Fig 29 Wiring diagram three phase Multilift MD MLD 22 3 4 with contactors Fig 30 Wiring diagram three phase Multilift MD MLD 24 3 2 MD ML...

Страница 22: ...hat the cable entry is watertight and that the cables are not bent sharply and or pinched Pump parts Remove eight screws and dismantle the pump from the tank and check that the vent hole of the pump h...

Страница 23: ...Lifting eye Fig 32 Top of slotted motor shaft Fig 33 Vent holes in pump housing and collecting tank Fig 34 Alignment marks on tank and pump flange 10 3 Electrical maintenance Check the gasket of the L...

Страница 24: ...ift MD MLD Fig 35 Removing the level sensor 10 5 Contaminated lifting station or components If Grundfos is requested to service the lifting station Grundfos must be contacted with details about the pu...

Страница 25: ...range All pumps are started and high level alarm is on a Discharge valves are not all opened Open all discharge isolating valves b There is a blockage in the tank or pump Remove blockage c The pump v...

Страница 26: ...ngs NBR rubber Controller Voltage variants rated voltages 1 x 230 V 3 x 230 V 3 x 400 V Voltage tolerances for LC 221 10 6 of rated voltage Mains frequency for LC 221 50 60 Hz Supply system earthing F...

Страница 27: ...Appendix 27 Appendix 1 Fig A Dimensional sketches MD TM05 0441 1011...

Страница 28: ...Appendix 28 Fig B Dimensional sketches MLD TM05 0442 1011...

Страница 29: ...53 428 5005 Korea GRUNDFOS Pumps Korea Ltd 6th Floor Aju Building 679 5 Yeoksam dong Kangnam ku 135 916 Seoul Korea Phone 82 2 5317 600 Telefax 82 2 5633 725 Latvia SIA GRUNDFOS Pumps Latvia Deglava b...

Страница 30: ...splayed in this material including but not limited to Grundfos the Grundfos logo and be think innovate are registered trademarks owned by The Grundfos Group All rights reserved 2018 Grundfos Holding A...

Отзывы: