background image

English (GB)

19

10.4 Position numbers

The position numbers in the table below refer to the 
constructional drawings in the appendix. See 
appendix, section 

Constructional drawings

.

1)

Can be ordered as seal ring kit.

2)

Can be ordered as mechanical seal kit.

3)

Is included in a repair kit.

For service kit numbers, please see Grundfos 
Product Center 
(http://product-selection.grundfos.com).

10.5 Returning the pump to the 

manufacturer

Before returning the pump, make sure the following 
requirements have been fulfilled:

The pump has been depressurized.

The pump is completely empty.

All electrical connections have been 
disconnected and the motor cannot be 
accidentally switched on again.

The pump has cooled down.

The coupling guard has been dismounted.

The spacer has been removed (if coupling is a 
spacer coupling).

Auxiliary systems have been shut down, 
depressurized and emptied.

Pressure gauge lines have been dismounted.

Before returning the pump to the manufacturer, take 
necessary measures, depending on the required 
repair work, as listed in the table below.

10.5.1 Contaminated products

The product will be classified as contaminated if it 
has been used for a liquid which is injurious to health 
or toxic.
If you request Grundfos to service the product, 
contact Grundfos with details about the liquid before 
returning the product for service. Otherwise, 
Grundfos can refuse to accept the product for 
service.
Any application for service must include details 
about the liquid.
Clean the product in the best possible way before 
you return it.
Costs of returning the product are to be paid by the 
customer.

10.6 Service documentation

Service documents are available in Grundfos 
Product Center 
(http://product-selection.grundfos.com).

Pos.

Description

1

Discharge casing

2

Rotor housing

3

Pump bracket

4

Suction casing

12

Drive screw

13

Idler screw

21

Labyrinth seal

22

Labyrinth seal

23

Spacer ring

24

Spacer ring

26

3)

Pressure balancing bush

100

3)

Gasket

121

3)

O-ring

122

3)

O-ring

129

O-ring

140

3)

Seal ring

160

Sealing plug

161

Sealing plug

183

1)

Shaft seal ring

186

2)

Mechanical shaft seal

200

Hexagon socket head cap screw

201

Stud bolt

214

Screw plug

220

Hexagon nut

230

3)

Thrust disc

251

Circlip

252

3)

Circlip

270

Inside ring

280

Rivet

290

Shaft key

292

3)

Deep-groove ball bearing

970

Nameplate

980

Plastic cover

981

Plastic cover

Repair to be 
carried out...

Action before return

... at the 
customer's 
premises:

• Dismount the defective 

component and return it to 
the manufacturer.

... at the 
manufacturer's 
premises:

• Flush the pump and 

decontaminate it if it was 
used for hazardous pumped 
liquids.

• Return the complete pump 

(not disassembled) to the 
manufacturer.

... at the 
manufacturer's 
premises for 
warranty repairs:

Содержание MTS 140

Страница 1: ...MTS Installation and operating instructions GRUNDFOS INSTRUCTIONS...

Страница 2: ...Handling and storing the product 13 6 1 Handling the product 13 6 2 Storing the product 13 6 3 Preparation for storage 13 6 4 Storage 13 6 5 Removing corrosion inhibitor 14 7 Operating conditions 14 7...

Страница 3: ...regulations safety regulations governing the handling of hazardous substances relevant standards and guidelines applying in the country where the pump is operated Make personal protective equipment a...

Страница 4: ...s required by regulations after any work on the pump 1 3 2 Specific hazard Observe the relevant safety regulations when handling hazardous pumped liquids hot flammable poisonous or potentially harmful...

Страница 5: ...pes of installation Tank top installation The pump is mounted on top of the tank using the holes in the discharge casing flange Thus discharge casing and pump bracket are above the tank top Fig 3 Tank...

Страница 6: ...ull are pipes depressurized or pressurized have flanges changed position 2 Make sure the used pipe supports do not damage the pipes due to friction and do not lose flexibility due to corrosion Pipe di...

Страница 7: ...Provide leak monitoring equipment Collect any leaking pumped liquid and dispose of it in accordance with local environmental rules and requirements 3 1 10 Connecting the pipes Keeping the pipes clean...

Страница 8: ...correct performance observe the requirements in the tables below Fig 7 Tank top installation TM05 3352 1312 Min liquid level Top of tank Min liquid level A A B DQ D8 6 Pump A mm B mm MTS 20 147 25 MT...

Страница 9: ...488 192 543 192 601 216 691 215 5 732 220 5 817 229 866 180 208 617 216 691 215 5 732 220 5 817 229 866 200 208 617 216 691 215 5 732 244 5 841 229 866 225 246 721 245 5 762 250 5 847 261 898 250 259...

Страница 10: ...inimum immersion depth 4 1 First start up 4 1 1 Removing the corrosion inhibitor Only necessary for pumps treated with corrosion inhibitor See section 6 5 Removing corrosion inhibitor 4 1 2 Priming 1...

Страница 11: ...void damage to the motor Note the maximum permissible number of starts per hour Consult the manufacturer about any other use of the pump When a pump is supplied without motor the pump unit must fulfil...

Страница 12: ...pressure bar Screw sense of gradient R right Screw pitch angle in degrees Construction D External ball bearing shaft seal unheated uncooled Shaft seal pipe connection Q Shaft seal ring axial inlet pi...

Страница 13: ...n 2 2 Handling the product 6 2 Storing the product The pump has not been treated for storage from factory 6 3 Preparation for storage Prepare the pump properly for storage both inside and outside Use...

Страница 14: ...is installed 4750 m above sea level the motor must not be loaded more than 88 of rated output At an ambient temperature of 75 C the motor must not be loaded more than 78 of rated output If the pump i...

Страница 15: ...Steel hard Tungsten carbide Titanium Process Drilling Turning milling Turning milling Grinding Grinding Grinding Grinding Tool High speed steel HSS Tungsten carbide Tungsten carbide Corundum Corundum...

Страница 16: ...ction side and discharge side valves and drain the pump by removing the drain plug and turning the pump manually until the pump is empty DQ Close the discharge side valve and empty the pump through th...

Страница 17: ...ses or vibrations no excessive leakage at the shaft seal 10 1 2 Bearings Intermittent operation high temperatures and aggressive ambient and process conditions reduce the service life of bearings Deep...

Страница 18: ...g dismantling Mark the precise orientation and position of all components before dismounting them Dismantle components concentrically without tilting them For dismantling of the pump see appendix sect...

Страница 19: ...ct contact Grundfos with details about the liquid before returning the product for service Otherwise Grundfos can refuse to accept the product for service Any application for service must include deta...

Страница 20: ...equipment CAUTION Hot or cold surface Minor or moderate personal injury Make sure that no one can accidentally come into contact with hot or cold surfaces Fault number Fault description Fault number...

Страница 21: ...d if speed control is available X X X Motor speed is too high Compare the required motor speed with the specifications on the pump nameplate Replace the motor if necessary Reduce the motor speed if sp...

Страница 22: ...the pump X X X Anti friction bearing in pump is defective Replace the anti friction bearing X X Anti friction bearing in motor is defective Replace the anti friction bearing X Discharge side valve is...

Страница 23: ...ews MTS 20 40 sectional drawings Fig 1 Sectional drawings of MTS 20 40 Can be ordered as spare part Remove the plastic cover before starting the pump Not with size MTS 40 TM05 2368 5011 TM05 2369 5011...

Страница 24: ...Appendix 24 MTS 20 40 exploded view Fig 2 Exploded view of MTS 20 40 TM04 2629 5011...

Страница 25: ...Appendix 25 MTS 20 model B sectional drawings Fig 3 Sectional drawings of MTS 20 model B Can be ordered as spare part Remove the plug before putting the pump into service TM05 3354 1312...

Страница 26: ...Appendix 26 MTS 20 model B exploded view Fig 4 Exploded view of MTS 20 model B TM05 2391 5011...

Страница 27: ...awings Fig 5 Sectional drawings of MTS 80 140 Can be ordered as spare part Remove the plastic cover before starting the pump TM05 2370 5011 TM05 2371 5011 D 8 6 SAE flange on suction side DQ Axial pip...

Страница 28: ...Appendix 28 MTS 80 140 exploded view Fig 6 Exploded view of MTS 80 140 TM04 2630 5011...

Страница 29: ...x 29 MTS 210 280 440 sectional drawings Fig 7 Sectional drawings of MTS 210 280 440 Can be ordered as spare part Remove the plug before putting the pump into service Not with size MTS 210 280 TM05 257...

Страница 30: ...Appendix 30 MTS 210 280 440 exploded view Fig 8 Exploded view of MTS 210 280 440 TM05 2575 0312...

Страница 31: ...A38 45 38x45 25x45 180 7 10 26 A42 55 48x50 19x50 0 5 26 A42 55 48x50 25x50 200 1 17 26 A42 55 55x50 19x50 7 11 28 A48 60 55x56 25x56 225 7 17 28 A48 60 55x56 25x56 Motor frame size MTS 210 MTS 280 M...

Страница 32: ...48x50 25x50 200 1 17 26 A42 55 55x50 19x50 3 4 28 A48 60 55x56 25x56 225 7 17 28 A48 60 55x56 25x56 Motor frame size MTS 210 MTS 280 MTS 440 LM LP mm S Coupling LM LP mm S Coupling LM LP mm S Couplin...

Страница 33: ...dichiara sotto la sua esclusiva responsabilit che il prodotto MTS al quale si riferisce questa dichiarazione conforme alle seguenti direttive del Consiglio riguardanti il riavvicinamento delle legisl...

Страница 34: ...1 51 E mail info_GDK grundfos com www grundfos com DK Estonia GRUNDFOS Pumps Eesti O Peterburi tee 92G 11415 Tallinn Tel 372 606 1690 Fax 372 606 1691 Finland OY GRUNDFOS Pumput AB Trukkikuja 1 FI 013...

Страница 35: ...hona 421 2 5020 1426 sk grundfos com Slovenia GRUNDFOS LJUBLJANA d o o Lesko kova 9e 1122 Ljubljana Phone 386 0 1 568 06 10 Telefax 386 0 1 568 06 19 E mail tehnika si grundfos com South Africa Grundf...

Страница 36: ...440 Trademarks displayed in this material including but not limited to Grundfos the Grundfos logo and be think innovate are registered trademarks owned by The Grundfos Group All rights reserved 2019 G...

Отзывы: