English (GB)
17
9. Starting up the product after
standstill
1. If the pump has been shut down for over six
years, take the following measures before
starting it up again:
– Replace elastomer seals (O-rings, shaft seal
rings).
– Replace anti-friction bearings in the pump.
– Replace the motor bearing, if necessary.
2. Carry out all steps as for the first start-up. See
section
9.1 Test run of the stand-by pump (if
installed)
Stand-by pump must be primed and vented.
Test run the stand-by pump at least once a week.
10. Servicing the product
10.1 Maintaining the product
10.1.1 Periodic checks
Make the following checks at regular intervals,
depending on the operational load on the pump:
•
Check that temperature of anti-friction bearings <
70 °C.
•
Check that normal operating conditions prevail.
•
Check that the pressure relief valve is working.
For trouble-free operation, always ensure the
following:
•
no dry running
•
no leaks
•
no cavitation
•
suction-side isolating valves open
•
unclogged and clean filters
•
sufficient pump inlet pressure
•
no unusual running noises or vibrations
•
no excessive leakage at the shaft seal.
10.1.2 Bearings
Intermittent operation, high temperatures and
aggressive ambient and process conditions reduce
the service life of bearings.
Deep-groove ball bearings are according to DIN 625.
The bearings are greased-for-life (cannot be
relubricated) and have sealing washers on both
sides.
As a precaution, replace greased-for-life bearings
every two years (recommended).
WARNING
Electric shock
Death or serious personal injury
- Before starting any work on the product,
make sure that the power supply has
been switched off and that it cannot be
accidentally switched on.
WARNING
Moving parts
Death or serious personal injury
- Tighten the coupling screws to the
correct torque.
- Install the coupling guards securely to
the pump with the screws intended for
this purpose.
CAUTION
Corrosive liquids
Death or serious personal injury
- Wear personal protective equipment.
CAUTION
Toxic liquids
Death or serious personal injury
- Wear personal protective equipment.
CAUTION
Hot or cold liquid
Minor or moderate personal injury
- Wear personal protective equipment.
CAUTION
Hot or cold surface
Minor or moderate personal injury
- Make sure that no one can accidentally
come into contact with hot or cold
surfaces.
Содержание MTS 140
Страница 1: ...MTS Installation and operating instructions GRUNDFOS INSTRUCTIONS...
Страница 24: ...Appendix 24 MTS 20 40 exploded view Fig 2 Exploded view of MTS 20 40 TM04 2629 5011...
Страница 26: ...Appendix 26 MTS 20 model B exploded view Fig 4 Exploded view of MTS 20 model B TM05 2391 5011...
Страница 28: ...Appendix 28 MTS 80 140 exploded view Fig 6 Exploded view of MTS 80 140 TM04 2630 5011...
Страница 30: ...Appendix 30 MTS 210 280 440 exploded view Fig 8 Exploded view of MTS 210 280 440 TM05 2575 0312...