English (GB)
21
X
X
-
X
X
-
-
-
Supply or suction pipe, rotor housing
or suction casing blocked or
encrusted.
• Clean the supply or suction pipe,
rotor housing or suction casing.
• Clean the suction casing.
X
X
-
X
X
-
-
-
Air is sucked in.
• Seal the source of air leakage or
repair the malfunctioning
component, if necessary.
X
X
-
X
X
-
-
-
Pump is cavitating due to excessive
amount of gas.
• Check the pipes.
• Clean or enlarge the filter.
• Install supply or suction pipe with
a bigger cross-section.
X
X
-
X
X
-
-
-
Excess play between:
• spindles
• spindles and housing.
• Repair or replace any worn parts.
X
X
-
X
-
-
X
-
Shaft seal is leaking excessively.
• Replace the shaft seal.
-
X
-
X
X
-
-
X Motor is running on two phases.
• Check the fuse and replace it, if
necessary.
• Check the cable connections and
insulation. Replace the cable, if
necessary.
-
X
-
X
-
-
-
-
Motor speed is too low.
• Compare the required motor
speed with the specifications on
the pump nameplate. Replace the
motor, if necessary.
• Increase the motor speed if speed
control is available.
-
-
X
-
X
-
-
X Motor speed is too high.
• Compare the required motor
speed with the specifications on
the pump nameplate. Replace the
motor, if necessary.
• Reduce the motor speed if speed
control is available.
-
X
-
X
-
-
-
-
Isolating valve in supply or suction
pipe is not fully opened.
• Open the valve completely.
-
X
-
X
X
-
-
-
Supply or suction pipe cross-section
is too small.
• Install supply or suction pipe with
a larger cross-section.
• Remove any encrustations from
the suction pipe.
• Open the valve completely.
-
X
-
X
X
-
-
-
Suction height too high: NPSH
pump
is larger than NPSH
system
.
• Increase the supply or inlet
pressure.
• Consult the manufacturer.
-
X
-
X
X
-
-
-
Pump is cavitating because pumped
liquid temperature is too high.
• Increase the supply or inlet
pressure.
• Lower the pumped liquid
temperature.
• Consult the manufacturer.
-
X
-
X
X
-
-
-
Hydraulic parts of the pump are dirty,
clotted or encrusted.
• Dismount the pump and clean the
parts.
-
X
-
X
-
-
-
X
Viscosity or specific gravity of the
pumped liquid is outside the range
specified for the pump.
• Consult the manufacturer.
-
X
-
X
X
X
-
-
Pump parts are worn.
• Replace the worn pump parts.
Fault number
Cause
Remedy
1
2
3
4
5
6
7
8
Содержание MTS 140
Страница 1: ...MTS Installation and operating instructions GRUNDFOS INSTRUCTIONS...
Страница 24: ...Appendix 24 MTS 20 40 exploded view Fig 2 Exploded view of MTS 20 40 TM04 2629 5011...
Страница 26: ...Appendix 26 MTS 20 model B exploded view Fig 4 Exploded view of MTS 20 model B TM05 2391 5011...
Страница 28: ...Appendix 28 MTS 80 140 exploded view Fig 6 Exploded view of MTS 80 140 TM04 2630 5011...
Страница 30: ...Appendix 30 MTS 210 280 440 exploded view Fig 8 Exploded view of MTS 210 280 440 TM05 2575 0312...