3 | How to start up the system
1. Open the valve on the raw water inlet.
2. Release a manual regeneration (chapter F). Starting from
the basic display, press and hold key
for 5 seconds.
An exchanger is now regenerated.
3. When the first manual regeneration has finished: Start a
manual regeneration again, the second exchanger is now
regenerated.
Note:
All systems with low-salt alarm have a delay time set bet-
ween 2 regenerations (factory setting: 0.2 hours = 12 minutes).
At the end of the regeneration, it is necessary to wait for this
time to elapse before a manual regeneration can be triggered
again.
4. Open the valve on the soft water outlet after regeneration has
finished.
5. Perform a visual check.
Ensure that no water leaks from the system at any point.
6. Take a water sample at the sampling valve downstream of
the system.
7. Perform a hardness test using the "Total hardness" water
inspection device.
The system is working correctly if the analysis of the water
taken just downstream of the exchanger tank gives 0 °dH.
8. Complete the cover sheet and check list / column 1 of the
operating log. To do this, carry out the necessary measure-
ments and tests.