Water softener
GENO-mat duo WE-X,
GENO-mat duo WE-OSMO-X
Order no. 074 184 046-inter Edited by: phar/mrie G:\BA-184046-inter_074_GENO-mat duo_WE-X.docx
25
2.2 How to fit the brine line
See Fig. D-1 (b), position 7.
1. Set up the brine tank at its intended site.
2. Remove cover from the brine tank.
Note:
Remove the brine valve to make installing the brine line
easier. To do so, remove the yellow lid and pull the brine valve
upwards.
Brine valve with transition nipple and
elbow connector
3. Fit the transition nipple (not needed with 750 (530)) and
elbow connector onto the brine valve.
4. Cut the brine hose to the required length and insert
reinforcing sleeves at both ends.
5. Fit the brine hose onto the brine valve.
6. Only if removed: Insert the brine valve and replace the
yellow cover.
3 | How to connect the system
3.1 Water connection
1. Make the water connection as indicated in the installation
drawing (Fig. D-1 (a)) while observing the guidelines and
recommendations given in section 1.
Note:
The supplied water meter must be installed on the soft
water side (after the system) without fail.
Caution!
Dirt and corrosion particles may damage the system
(control valve, ion exchanger resin). Flush the supply pipe prior
to start-up.
2. Make the waste water connection: Direct the drain hose to
the outlet and secure it.
Caution!
Danger of damage and malfunction due to backflow of
waste water. Therefore, do not bend the hose and do not lead it
higher than the system height.
3. Route the brine tank overflow hose with a gradient to the
channel. Do not connect to the drain hose!
Содержание GENO-mat duo WE-OSMO-X 130