E Start-up
The work described below may only be performed by trained
experts. For safety reasons, the start-up must be performed by
Grünbeck's trained and authorised technical customer
service/authorised service company.
1 | How to fill the brine tank
1. Remove the cover from the brine tank
2. Carefully add water until the water level is about 30 mm
above the sieve base.
Caution!
Insoluble impurities in the salt may cause malfunctions
at the brine valve and at the injector of the control valve.
A defined salt quality is required for the reliable function of the
water softener.
Only use salt tablets that conform to DIN EN 973 A.
3. Insert salt tablets into the brine tank. The brine tank can be
fully filled.
4. Add the operating water volume (Table E-1).
5. Close the brine tank cover.
Table E-1: Filling of brine tank
Water softener GENO-mat duo WE-X /
GENO-mat duo WE-OSMO-X
Systems with full salting
65
150
300
450
750
Max. regeneration salt supply *
[kg]
130
190
285
485
760
Operating water volume
[l]
10
22
45
70
111
Table E-2: Filling of brine tank
Water softener GENO-mat duo WE-X
Systems with economy salting
50
130
230
330
530
Max. regeneration salt supply *
[kg]
65
130
190
285
285
Operating water volume
[l]
5
11
23
32
44