Malfunction (error shown on LCD / LED)
“Normal“ operating mode
: Lubricus Controller display „ON” each LED for activated pumps blink shortly one after each
other in 1 second intervals. Not activated Lubricus Controller exits will not blink
Example:
Lubricus Controller exit 1: Lubricus LUB-C-2: Adjustment green LED / left Lubricus body:
2 exits = A02
Adjustment orange LED / right Lubricus body: 0 exits = A00
Lubricus Controller exit 2: Lubricus LUB-C1-1: Adjustment green LED / left Lubricus body:
1 exit = A01
Adjustment orange LED / right Lubricus body: 1 exit = A01
Green LED for normal operating mode is always illuminated, LED’s of Lubricus Controller exit 1 and 2 blink shortly one after
each (green, green ,orange , and starting again from the beginning …)
Error messages / faults
: The dedicated error message for each connected Lubricus unit is displayed.
E1
:
Empty lubricant reservoir
: red LED lights cons Display will show error for Lubricus unit connected to Lubricus
Controller exit + E1, when the sequence of the connected pump with the error is reached. If the sequence reaches the units
without error the display will show “ON”, the red LED will still light to signal that an error message exists.
Root cause:
The lubricant cartridge is empty. The unit continues to be active and will pump!
Corrective action: replace cartridge. Lubricus will continue to run as per active program.
Example: exit 1, Lubricus LUB-C-2, all OK exit 2, Lubricus LUB-C-1-1, cartridge empty
E2
:
Back pressure too high
:
red LED lights cons Display will show error for Lubricus unit connected to Lubricus
Controller exit + E2; the error message is related to the Lubricus body half respectively to the Lubricus exit.
Root cause:
Back pressure was measured 3 x too high. The lubrication point could be clocked, the tube length could
be too long or the grease is too stiff or has hardened. Lubricus will stop!
Corrective action: Trace reason for high back pressure >70bar and correct it.
Switch unit „OFF“ and „On“ again. The error message will be reset to 0. Lubricus will start again as per
program in memory.
Example:
Exit 2, Lubricus LUB-C-1-1, Error 2E2 at exit 2 + orange LED / right Lubricus body half: exit1