U
24V
0V
t
PIN 4
1s
1s
1s
1s
1s
1s
1s
8.3.1 Error E1 (empty level) - external control (PLC)
LUB-V is equipped with a sensor which detects the empty level of the lubricant cartridge.
After reaching the empty level, LUB-V no longer dispenses lubricant. This ensures that
no air enters LUB-V or the lubricant lines. The empty state message (error E1) is trans-
mitted to the external control (PLC). For this purpose, a separate, unique output signal is
provided which can be easily and reliably detected by the external control (PLC).
Description:
LUB-V is properly connected to an external controller via the electrical interface and
connected to the power supply.
Pulse control mode PUL is activated on LUB-V, E1 is displayed in the LCD and the red
LED lights up.
l
Error E1 (empty state signal) can only occur immediately after a dispense.
l
Error E1 (empty state signal) must not and cannot be acknowledged. Remedial action
is described in chapter 9.2. When removing the cartridge LUB-V sends a permanent
square wave signal as output signal to PIN 4.
LUB-V does not process any control signals until all errors have been eliminated.