![Gruetzner LUB-V Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/gruetzner/lub-v/lub-v_user-manual_2270801032.webp)
32
6.3.6 RUN menu
The RUN menu is used to manually activate LUB-V and enables triggering an extra
dispense. This function can be used, for example, to manually check the condition of the
lubrication point ("quick check").
LUB-V carries out a special dispense after triggering the RUN function. After triggering
the RUN function, LUB-V executes exactly as many strokes per outlet as were set in
the variable number of cycles c in the PRO menu. During the stroke, the back pressure
detected by the integrated microelectronics is displayed in the LCD as an approximate
value in bar.
There is no fault or error at LUB-V.
l
Remove the activation and programming key from the top of LUB-V and place it onto
the action area.
l
Hold the activation and programming key onto the action surface. The yellow LED
lights up. Leave the activation and programming key on the action area until RUN is
displayed in the LCD. Remove the activation and programming key from the action area
as long as RUN is displayed. The yellow LED disappears.
Ü
The LCD and the green LED flash twice. LUB-V starts to pump the lubricant to the
outlet (extra dispense or "Quick check") depending on the value c set in PRO menu. (E.g.
if c=1 is set, the RUN function triggers one stroke. If c=4 is set, 4 strokes are dispensed.)
l
Insert the activation and programming key into the hole provided on top of LUB-V or
repeat the extra dispense ("Quick check") if necessary.
l
Observe the back pressure values displayed on the LCD if they are of interest.
During the dispensing process, the green LED lights up; in addition, the counterpres-
sure for the stroke is displayed in the LCD.
The RUN menu can only be reached from the ON mode (LUB-V switched on). When
you have entered the RUN menu, you will return to the ON mode.