7.3
Output signals at PIN 4 - time control
LUB-V provides two output signals in hour mode -h (factory setting) via the electrical in-
terface. If required, the operating states of LUB-V can be processed externally. Basically,
the output signals can only be sampled and must not be subjected to inductive loads or
low ohmic loads. Besides LCD and LED this also allows a status control from a distance.
Output signal high level (+24 V) at PIN 4:
Description:
A permanently and continuously present high level (+24 V) at PIN 4 means that LUB-V
is ready for operation and there is no error. LUB-V will operate according to the settings
made and will accordingly convey lubricant from the cartridge to the outlet.
Description:
A permanent low level (0V) at PIN 4 means that LUB-V is either switched off or - if it
is switched on - an error occured. The error must be read out from the LCD of LUB-V
(chapter 6.4). LUB-V does not pump lubricant!
Output signal low level (0 V) at PIN 4: