7.1.2
Set inverter time and date
Method
1
:
Please
refer
to
section
8
.
2
.
1
and
login
ShinePhone
APP.Click
"
system
time
(
45
-
50
)"
to
set
inverter
time
and date on the parameter
setting
page.
Method
2
:
Please
connect
GPRS
antenna
to
the
inverter
as
section
6
.
3
.
3
,
when
the
inverter
is
powered
on
,
connect
the
inverter
to
the
server
as
section
8
.
1
.
2
,
then
the
inverter
time
will
be
updated
automatically
.
7.2
Operation Mode
28
27
Fig
7
.
2
7.3
LED Display
7.2
.
1
Waiting
mode
7.2
.
2
Working
mode
7.2
.
3
Fault
mode
7.2
.
4
Off
mode
When
the
DC
voltage
is
more
than
200Vdc
,
inverter
will
be
powered
on
and enters the
"waiting" state.
At
this
mode
,
inverter
will
check
the
system
parameter
.
If
the
system
is
normal
and
PV
voltage
is
more
than
250Vdc
,
inverter
will
try
to
connect
to
the
grid
.
At
this
mode
,
inverter
work
normally
,
and
the
shows
the power delivered by the inverter to the grid
.
When
the
DC
voltage
is
more
than
250Vdc
,
inverter converts the DC power generated by
the PV modules into AC power and supplies them to the grid
.
When
the
DC
voltage
is
lower
than
250Vdc
,
inverter
will
enter
into “waiting”
state
and
try
to
connect
to
the
grid
,
at
this
status
,
inverter
consume
very
small
power
to
check
the
internal
system
status
.
Note
:
only
when
the
PV
modules
supply
enough
power
(
voltage
>
200Vdc
)
then
the
inverter
will
start
automatically
.
Power or fault code indicator light
Inverter
intelligent
control
system
will
continuously
monitor
and
adjust
system
status
.
When
there
is
a
fault
detected
,
LED
will
show
the
fault
message
.
Note: Please
refer
to
section
8
.
2
to
check
the
fault
message
and
take
corrective
measures
.
When
the
sunlight
is
weak
or
no
light
,
inverter
will
stop
working
automatically
.
When
it
is
off
,
inverter
will
not
consume
gird
power
or
PV
module
.
At the same time, the LED of
inverter will be turned off.
Note: When
PV
string
DC
voltage
is
too
low(
≤
150Vdc
),
inverter
will
be
off
.
Inverter
current
operation
status
can
be
visually
checked
from
LED
display
directly
.
A
B
C
D
E
Fig
7
.
4
Fig
7
.
3
Description of LED status
Position
of LED
Type of
LED
Inverter status
LED status
A
PV voltage
indicator
light
PV voltage reaches grid
voltage
Green light is on
PV voltage does not reach
the grid voltage
Light is not on
B
AC voltage
indicator
light
Inverter is in the grid state
Green light is on
No AC voltage
Light is not on
With AC voltage, inverter
is in the grid countdown
state
The green light flashes
slowly, and the alarm or
fault indicator light is not on