background image

45

46

2)  By

 

clicking

 

on

 "

power

 

station

and

 "

equipment

 

management

in

 

turn

the

 

real

-

time

 

data

 

of

  "

data

 

collector

",  "

inverter

",  "

environment

 

monitor

",  "

intelligent

 

meter

and

 

"

confluence

 

box

MAX

 "

can

 

be

 

viewed

.

8.2 Local

 

Data

 

Monitoring

8

.

2

.

1

 

Mobile

 

phone

 

app

 (

Shinephone

Local

 

Monitoring

8

.

2

.

1

.

1

 

Log

 

on

 

to

 

app

 

for

 

local

 

monitoring

MAX

 

Inverter

 

local

 

data

 

monitoring

 

mode

 

has

 

a

 

mobile

 

phone

 

app

 

phone

and

 

PC

 

direct

 

connection

udisk

details

 

are

 

as

 

follows

.

Method

 

1

When

 

you

 

open

 

the

 

app

 

login

 

front

 

page

click

 

the

 

top

 

right

 

corner

 

toolbox

 

icon

Pop

 

up

 

the

 

toolbox

click

 

the

 

local

 

debugging

 

tool

and

 

you

 

can

 

get

 

the

 

wifi

 

name

 

of

 

the

 

collector

 

by

 

scanning

 

the

 

QR

 

code

 

or

 

barcode

(

The

 

default

 

password

 

for

 

WIFI

 

is 

12345678

If

 

you

 

have

 

already

 

connected

you

 

can

 

click

 "

Skip

to

 

connect

 

directly

 

to

 

the

 

WIFI

.)

Method

 

2

Open

 

app

 

enter

 

user

 

name

 

and

 

password

 

click

 

login

enter

 

me

  (

personal

 

center

). 

Click

 

the

 

enter

 

tool

find

 

the

 

local

 

debugger

 

to

 

enter

and

 

you

 

can

 

get

 

the

 

wifi

 

name

 

of

 

the

 

collector

 

by

 

scanning

 

the

 

QR

 

code

 

or

 

barcode

(

The

 

default

 

password

 

for

 

WIFI

 

is

 

12345678

If

 

you

 

have

 

already

 

connected

you

 

can

 

click

 "

Skip

to

 

connect

 

directly

 

to

 

the

 

WIFI

.)

Fig 8.34

8

.

2

.

1

.

2

 

Use

 

of

 

local

 

monitoring

 

and

 

debugging

When

 

viewing

 

local

 

monitoring

you

 

must

 

keep

 

the

 

phone

'

s

 

wifi

 

connected

 

to

 

the

 

collector

'

s

 

wifi

 

to

 

view

 

local

 

monitoring

  (

to

 

enter

 

the

 

local

 

monitoring

 

page

first

 

click

 

auto

 

refresh

 

to

 

get

 

the

 

latest

 

data

 

information

). 

Electricity

 

generation

the

 

option

 

to

 

view

 

the

 

latest

 

generation

daily

 

generation

monthly

 

and

 

annual

 

generation

 

of

 

detailed

 

information;

 

Power

you

 

can

 

see

 

the

 

current

 

power

 

and

 

rated

 

power

 

value;

 

failure:  can

 

read

 

the

 

equipment

 

detailed

 

fault

 

information.

1>device

 

control

Note:  In

 

addition

 

to

 

resetting

 

the

 

password

 

to

 

connect

 

to

 

the

 

network

other

 

WIFI 

modules

 

that

 

must

 

connect

 

to

 

the

 

collector

 

can

 

view

 

information

.

A.Reset

 

password

Need

 

network

 

connection

 

login

 

oss

 

account

 

to

 

set

 

up

 

or

 

modify

 

the

 

local

 

debug

 

password.

B.Setting

 

configuration

The

 

configuration

 

data

 

of

 

inverter

voltage

power

 

and

 

so

 

on

 

can

 

be

 

modified

 

according

 

to

 

the

 

usage

 (

Fig 8.36)

.

Fig 8.35

Содержание MAX 50KTL3 LV

Страница 1: ...EN GROWATT NEW ENERGY TECHNOLOGY CO LTD No 28 Guangming Road Shiyan Street Bao an District Shenzhen P R China T 86 755 27471942 E service ginverter com W www ginverter com Installation Operation Manua...

Страница 2: ...roduction 4 Unpacking 5 Installation 5 1 Basic Installation Requirements 5 2 Installation Environment Requirements 5 3 Moving Requirements 5 4 Wall Mounted Installation 5 5 Installing the Inverter 3 1...

Страница 3: ...ound Cables 6 Connecting Cables 11 Decommissioning 7 System Commissioning 12 Quality Assurance 7 1 Inverter Commissioning 7 2 Modes 7 3 LED display 8 1 Remote Data Monitoring 8 2 Local Data Monitoring...

Страница 4: ...any warranty Before installation please read through this manual any damage Ensure that the MAX is not connected to a power supply and is not power on before installation at OFF also disconnect AC sw...

Страница 5: ...hnician Burn Warning Do not touch a running inverter cause it generates high temperature on the case Protective Grounding Connect inverter to grounding bar Delay discharge Residual voltage exists afte...

Страница 6: ...Size mm Weight kg Width Height Thickness 50 80K Inverters 860 600 300 82 50 80K Inverter with package 1035 735 465 98 3 3 Nameplate Note Other models of MAX series share the same label design with MA...

Страница 7: ...400V 400V 230V 230V 230V 480V 480V 480V Fig 3 5 Fig 3 6 AFCI Arc Fault Circuit Interrupter is a kind of circuit protection device the main function is to prevent the fire caused by fault arc The elec...

Страница 8: ...le or heat intolerant buildings D This inverter is IP 65 protection you can install it indoor or outdoor E To avoid inverter performance de rate due to the over heat please do not expose the inverter...

Страница 9: ...nstall multiple inverters on one surface inverters should be installed as following drawing D Do not install inverter into an enclosed space like following drawing Fig 5 6 12 11 5 3 Moving Requirement...

Страница 10: ...ls with at least 100mm thickness 5 5 Installing The Inverter After the wall mount bracket has been firmly installed on the wall put the inverter on that plate 1 Use the rope must meet the weight requi...

Страница 11: ...nverters It is forbidden to add load between inverter and breaker Each inverter must install one AC breaker AC breaker is forbidden to share Preparation before connection 1 Disconnect inverter DC swit...

Страница 12: ...ll be a risk of water 1 Following drawing shows inverter s AC terminal L1 L2 L3 are three live lines N is Neutral line Notice The screw is M8 screw inner ground connection AC terminal block Fig 6 1 2...

Страница 13: ...s maximum single string input current please refer to following table Inverter model Max single string input current MAX serial inverter 13A 2 7 Cable specifications Inverter model Cross sectional ar...

Страница 14: ...ring function In addition you can quickly update the software via a USB flash drive Steps to install the monitoring module 1 Loose waterproof cover and remove waterproof plug 2 As shown in Figure 6 8A...

Страница 15: ...down conductor and the equipment ground wire eventually sink at a total ground point but the two cannot share the wire That is the equipment grounding wire should be pulled separately and the wire di...

Страница 16: ...to 8 2 download mobile APP ShinePhone and connect to inverter WIFI to enter local monitoring page this operation is performed by a professional 1 Click Parameters 2 Enter passwor When you use it for t...

Страница 17: ...at this status inverter consume very small power to check the internal system status Note only when the PV modules supply enough power voltage 200Vdc then the inverter will start automatically Power o...

Страница 18: ...LED status B AC voltage indicator light With AC voltage inverter is in a fault state The green light flashes slowly and the alarm or fault indicator light is steady red C Alarm or fault indicator ligh...

Страница 19: ...device and edit edit operation includes change device alias icon and delete device Fig 8 7 2 User can add datalogger at the datalogger list page to add a datalogger edit delete configure etc 3 User ca...

Страница 20: ...back to login page input the registered username and password click Sign In Fig 8 13 Fig 8 14 2 Add datalogger At Plant page click device manage then click add datalogger input the SN and valid code t...

Страница 21: ...ding A Basic production reading Energy today total production revenue today and accumulative revenue are showing on this page Fig 8 19 Fig 8 17 shenzhen B Plant data page can check device power voltag...

Страница 22: ...ts with a high speed CPU and a stable Linux system that intelligently records the user s system characteristics Feature 1 A versatile and high performance communication data logger that notifies the u...

Страница 23: ...tor for operation Note The router needs to enable automatic IP assignment that is open the DHCP function C Enter the shinemaster IP address in the browser to enter the shinemaster built in page 2 Shin...

Страница 24: ...toring mode for monitoring photovoltaic devices in the first drop down list of add or remove devices Fig 8 27 2 Select the type of photovoltaic device monitored in the second drop down list 3 Fill in...

Страница 25: ...the first time please register the user name Enter the domain name access page as shown in figure 8 32 below Chinese user server domain name http server cn growatt com The domain name of the internat...

Страница 26: ...can get the wifi name of the collector by scanning the QR code or barcode The default password for WIFI is 12345678 If you have already connected you can click Skip to connect directly to the WIFI Fig...

Страница 27: ...ipment can be modified according to the usage 8 37 D Intelligent detection Detailed and accurate view of the device s detailed data and status Fig 8 38 Fig Fig 8 36 Fig 8 37 E Intelligent I V curve sc...

Страница 28: ...ick diagnosis I V curve diagnosis grid waveform THDV and cable impedance detection all at one click Fig 8 42 I High level setting According to the register address set parameters professionals J Devic...

Страница 29: ...needs to be programming at last time Fig 8 44 8 2 2 U Disk Monitoring Fig 8 45 2 Fault Recording Create the bconfig txt file under the root of the U disk write the following content then insert the U...

Страница 30: ...nce of load derating Inverter equipped with internal cooling fans when the internal temperature is too high the fans work in to reduce the internal temperature When the inverter is derating because of...

Страница 31: ...that need to replace with a cross screwdriver replace a new fan 4 Tidy up the wire 5 Install the fan fan guard fixed and the inverter again 9 2 Trouble Shooting 9 2 1 Warning Work on the Growatt Max m...

Страница 32: ...shows below may indicate a fatal error and require you to contact the supplier or Growatt for help Countercurrent prevention or Reactive power dispatching failure alarm Error Code Description Suggesti...

Страница 33: ...or module STC 75000W 90000W 105000W 120000W Max DC voltage 1100V Start voltage 250V Nominal voltage 585V 585V 600V 600V MPP voltage range 200V 1000V No of MPP trackers 6 6 7 7 No of PV strings per MPP...

Страница 34: ...0KTL3 MV MAX 70KTL3 MV MAX 80KTL3 MV MAX 90KTL3 MV MAX 100KTL3 MV Input Data DC Max recommended PV power for module STC 9000W 105000W 120000W 130000W 130000W Max DC voltage 1100V Start voltage 250V No...

Страница 35: ...RG DEWA 2016 BDEW G59 3 EMC EN61000 6 2 EN61000 6 4 Safety IEC EN62109 1 IEC EN62109 2 Note1 Self consumption less then 25W when AC power supply at night Model MAX 60KTL3 MV MAX 70KTL3 MV MAX 80KTL3 M...

Страница 36: ...e accordance with the disposal regulations for electronic waste which apply at the installation site at that time Ensure that the old unit and where applicable any accessories are disposed of in a pro...

Отзывы: