background image

1

 

Overview

1.1 Product Overview

This

 

manual

 

is

 

aimed

 

at

 

providing  sufficient

 

information

 

and

 

installing

 

instruction

 

for

 

consumers

 

buying

 

Shenzhen

 

Growatt

 

New

 

Energy

 

Technology

 

Co

.,

Ltd

 (

short

 

as

 

Growatt

MAX

 

Series

 

solar

 

inverters

Please

 

read

 

this

 

manual

 

carefully

 

before

 

using

 

the

 

MAX

 

series

 

inverters

 

and

 

store

 

the

 

manual

 

in

 

a

 

reachable

 

place

 

for

 

an

 

authorized

 

technician

No

 

further

 

notice

 

if

 

there

 

is

 

any

 

change

 

in

 

this

 

manual

.

1

.

2 Applicable

 

Personnel

Only

 

qualified

 

electrical

 

technicians

 

are

 

allowed

 

to

 

install

 

MAX

 

series

 

inverter

With 

reading

 

through

 

this

 

manual

 

and

 

following

 

all

 

the

 

precautions

qualified

 

electrical

 

technician

 

can

 

properly

 

install

 

MAX

 

serial

 

inverter

finish

 

trouble

 

shooting

 

and

 

communication settings

.

If

 

there

 

is

 

any

 

problem

 

during

 

the

 

installation

the

 

installer

 

can

 

either

 

log

 

on

 

www

.

ginverter

.

com

 

and

 

leave

 

a

 

message

 

or

 

call  consumer

 

service

 

hotline

  +

86

 

755

 

27471942.

2

 

Safety

 

Precautions

2

.

1

 

Safety

 

Overview

1>Before

 

installation

 

please

 

make

 

sure

 

reading

 

through

 

this

 

manual

any

 

damage

 

caused 

by

 

improper

 

installation

Growatt

 

reserve

 

the

 

right

 

to

 

disclaim

 

any

 

warranty

.

2>All

 

the

 

operations

 

and

 

connections

 

must

 

be

 

done

 

by

 

trained

 

qualified

 

electrical 

technician.

3>During

 

installation

 

except

 

for

 

terminals, do

 

not

 

touch

 

any

 

inside

 

part

 

of

 

the

 

inverter.

4>All

 

the

 

electrical

 

connections

 

must

 

meet

 

local

 

country's

 

safety

 

regulations.

5>If

 

you

 

need

 

maintenance

 

for

 

this

 

inverter

please

 

contact

 

our

 

local

 

authorized 

installing

 

and

 

maintenance technician.

6>You

 

must

 

get

 

the

 

local

 

power

 

supplier's

 

permit

 

before

 

connecting

 

this

 

inverter

 

to

 

the

 

grid

.

H a n d l e

 

P ro c e s s

Installation

Electrical

 

Connections:

Maintenance

 

and

 

replacement

:

•The inverter is heavy,please treat with care while handling,in case of 

crushing injury.


cause  by  improper  installation,Growatt  reserve  the  right  to  disclaim 

any warranty.

Before  installation,please  read  through  this  manual,any  damage 

•Ensure  that  the  MAX  is  not  connected  to  a  power  supply  and  is  not 

power on before installation.


at 

"

OFF”  also

 

disconnect

 

AC

 

switch

otherwise

 

the

 

high

 

voltage

 

from

 

inverter

 

may

 

cause

 

life

 

risk

.

•Only

 

trained

 

authorized

 

electrical

 

technician

 

can

 

do

 

the

 

electric

 

connection

 

also

 

please

 

follow

 

the

 

connection

 

procedures

 

in

 

this

 

manual

 

along

 

with

 

local

 

country's

 

regulations

.

•High

 

voltage

 

may

 

cause

 

electric

 

shocks

 

and

 

serious

 

injury

 

please

do

 

not

 

touch

 

the

 

inverter

.

•Please

 

do

 

not

 

store

 

inverter

 

in

 

area

 

with

 

flammable

 

and

 

explosive

 

material

.

Before

 

electrical

 

connection

please

 

ensure

 

the

 

inverter

 

DC

 

switch

 

is

 


accurately

 

follow

 

this

 

manual

.

•Please

 

disconnect

 

the

 

DC

 

and

 

AC

 

switch

 

for

 

at

 

least

 

five

 

minutes

all

 

the

 

operations

 

should

 

be

 

carried

 

after

 

power

 

disconnection

.

•If

 

there

 

is

 

PV

 

isolation

 

low

 

alarm

the

 

inverter

 

case

 

may be ungrounded,

please

 

do

 

not

 

touch

 

the

 

inverter

 

case

.

•High

 

voltage

 

of

 

inverter

 

may

 

result

 

in

  

electric

 

shock

.

Must

 

be

 

installed

 

by

 

trained

 

and

 

authorized

 

electrical

 

technician

 

and

 

•Each

 

inverter

 

must

 

install

 

one

 

AC

 

breaker;

 

AC

 

breaker

 

is

 

forbidden

 

to

 

share

 

with

 

other

 

inverters

.

•It

 

is

 

forbidden

 

to

 

add

 

load

 

between

 

inverter

 

and

 

breaker

.

•If

 

the

 

cable

 

is

 

thick

after

 

tightening

 

the

 

cable

 

do

 

not

 

shake

 

it  and

ensure

 

the

 

cable

 

is

 

well

-

connected

 

and

 

then

 

start  the

 

inverter

.

Loose

 

connection

 

may

 

cause

 

overheat

.

•Before

 

connecting

 

between

 

PV

 

panels

 

and

 

inverter

 

please

 

ensure

 

the

 

positive

 

and

 

negative

 

poles

 

are

 

correct

 

connected

.


•Do

 

not

 

use

 

air

 

pump

 

to

 

clean

 

the

 

fans

cause

 

it

 

may

 

damage

 

the

 

fans

.

For

 

better

 

cooling

 

purpose

please

 

regularly

 

clean

 

the

 

fans

.   

1

2

•Please

 

follow  this  installation  manual  as  installation  condition 

environment,space and so on.

• P l e a s e   i n s t a l l   t h e   i n v e r t e r   i n   a   d r y   a n d   v e n t i l a t e d  

environment,otherwise may affect the performance of the inverter.

•Please follow the installation procedures in this manual.

WARNING

WARNING

DANGER

 DANGER

 DANGER

NOTICE

 WARNING

WARNING

Содержание MAX 50KTL3 LV

Страница 1: ...EN GROWATT NEW ENERGY TECHNOLOGY CO LTD No 28 Guangming Road Shiyan Street Bao an District Shenzhen P R China T 86 755 27471942 E service ginverter com W www ginverter com Installation Operation Manua...

Страница 2: ...roduction 4 Unpacking 5 Installation 5 1 Basic Installation Requirements 5 2 Installation Environment Requirements 5 3 Moving Requirements 5 4 Wall Mounted Installation 5 5 Installing the Inverter 3 1...

Страница 3: ...ound Cables 6 Connecting Cables 11 Decommissioning 7 System Commissioning 12 Quality Assurance 7 1 Inverter Commissioning 7 2 Modes 7 3 LED display 8 1 Remote Data Monitoring 8 2 Local Data Monitoring...

Страница 4: ...any warranty Before installation please read through this manual any damage Ensure that the MAX is not connected to a power supply and is not power on before installation at OFF also disconnect AC sw...

Страница 5: ...hnician Burn Warning Do not touch a running inverter cause it generates high temperature on the case Protective Grounding Connect inverter to grounding bar Delay discharge Residual voltage exists afte...

Страница 6: ...Size mm Weight kg Width Height Thickness 50 80K Inverters 860 600 300 82 50 80K Inverter with package 1035 735 465 98 3 3 Nameplate Note Other models of MAX series share the same label design with MA...

Страница 7: ...400V 400V 230V 230V 230V 480V 480V 480V Fig 3 5 Fig 3 6 AFCI Arc Fault Circuit Interrupter is a kind of circuit protection device the main function is to prevent the fire caused by fault arc The elec...

Страница 8: ...le or heat intolerant buildings D This inverter is IP 65 protection you can install it indoor or outdoor E To avoid inverter performance de rate due to the over heat please do not expose the inverter...

Страница 9: ...nstall multiple inverters on one surface inverters should be installed as following drawing D Do not install inverter into an enclosed space like following drawing Fig 5 6 12 11 5 3 Moving Requirement...

Страница 10: ...ls with at least 100mm thickness 5 5 Installing The Inverter After the wall mount bracket has been firmly installed on the wall put the inverter on that plate 1 Use the rope must meet the weight requi...

Страница 11: ...nverters It is forbidden to add load between inverter and breaker Each inverter must install one AC breaker AC breaker is forbidden to share Preparation before connection 1 Disconnect inverter DC swit...

Страница 12: ...ll be a risk of water 1 Following drawing shows inverter s AC terminal L1 L2 L3 are three live lines N is Neutral line Notice The screw is M8 screw inner ground connection AC terminal block Fig 6 1 2...

Страница 13: ...s maximum single string input current please refer to following table Inverter model Max single string input current MAX serial inverter 13A 2 7 Cable specifications Inverter model Cross sectional ar...

Страница 14: ...ring function In addition you can quickly update the software via a USB flash drive Steps to install the monitoring module 1 Loose waterproof cover and remove waterproof plug 2 As shown in Figure 6 8A...

Страница 15: ...down conductor and the equipment ground wire eventually sink at a total ground point but the two cannot share the wire That is the equipment grounding wire should be pulled separately and the wire di...

Страница 16: ...to 8 2 download mobile APP ShinePhone and connect to inverter WIFI to enter local monitoring page this operation is performed by a professional 1 Click Parameters 2 Enter passwor When you use it for t...

Страница 17: ...at this status inverter consume very small power to check the internal system status Note only when the PV modules supply enough power voltage 200Vdc then the inverter will start automatically Power o...

Страница 18: ...LED status B AC voltage indicator light With AC voltage inverter is in a fault state The green light flashes slowly and the alarm or fault indicator light is steady red C Alarm or fault indicator ligh...

Страница 19: ...device and edit edit operation includes change device alias icon and delete device Fig 8 7 2 User can add datalogger at the datalogger list page to add a datalogger edit delete configure etc 3 User ca...

Страница 20: ...back to login page input the registered username and password click Sign In Fig 8 13 Fig 8 14 2 Add datalogger At Plant page click device manage then click add datalogger input the SN and valid code t...

Страница 21: ...ding A Basic production reading Energy today total production revenue today and accumulative revenue are showing on this page Fig 8 19 Fig 8 17 shenzhen B Plant data page can check device power voltag...

Страница 22: ...ts with a high speed CPU and a stable Linux system that intelligently records the user s system characteristics Feature 1 A versatile and high performance communication data logger that notifies the u...

Страница 23: ...tor for operation Note The router needs to enable automatic IP assignment that is open the DHCP function C Enter the shinemaster IP address in the browser to enter the shinemaster built in page 2 Shin...

Страница 24: ...toring mode for monitoring photovoltaic devices in the first drop down list of add or remove devices Fig 8 27 2 Select the type of photovoltaic device monitored in the second drop down list 3 Fill in...

Страница 25: ...the first time please register the user name Enter the domain name access page as shown in figure 8 32 below Chinese user server domain name http server cn growatt com The domain name of the internat...

Страница 26: ...can get the wifi name of the collector by scanning the QR code or barcode The default password for WIFI is 12345678 If you have already connected you can click Skip to connect directly to the WIFI Fig...

Страница 27: ...ipment can be modified according to the usage 8 37 D Intelligent detection Detailed and accurate view of the device s detailed data and status Fig 8 38 Fig Fig 8 36 Fig 8 37 E Intelligent I V curve sc...

Страница 28: ...ick diagnosis I V curve diagnosis grid waveform THDV and cable impedance detection all at one click Fig 8 42 I High level setting According to the register address set parameters professionals J Devic...

Страница 29: ...needs to be programming at last time Fig 8 44 8 2 2 U Disk Monitoring Fig 8 45 2 Fault Recording Create the bconfig txt file under the root of the U disk write the following content then insert the U...

Страница 30: ...nce of load derating Inverter equipped with internal cooling fans when the internal temperature is too high the fans work in to reduce the internal temperature When the inverter is derating because of...

Страница 31: ...that need to replace with a cross screwdriver replace a new fan 4 Tidy up the wire 5 Install the fan fan guard fixed and the inverter again 9 2 Trouble Shooting 9 2 1 Warning Work on the Growatt Max m...

Страница 32: ...shows below may indicate a fatal error and require you to contact the supplier or Growatt for help Countercurrent prevention or Reactive power dispatching failure alarm Error Code Description Suggesti...

Страница 33: ...or module STC 75000W 90000W 105000W 120000W Max DC voltage 1100V Start voltage 250V Nominal voltage 585V 585V 600V 600V MPP voltage range 200V 1000V No of MPP trackers 6 6 7 7 No of PV strings per MPP...

Страница 34: ...0KTL3 MV MAX 70KTL3 MV MAX 80KTL3 MV MAX 90KTL3 MV MAX 100KTL3 MV Input Data DC Max recommended PV power for module STC 9000W 105000W 120000W 130000W 130000W Max DC voltage 1100V Start voltage 250V No...

Страница 35: ...RG DEWA 2016 BDEW G59 3 EMC EN61000 6 2 EN61000 6 4 Safety IEC EN62109 1 IEC EN62109 2 Note1 Self consumption less then 25W when AC power supply at night Model MAX 60KTL3 MV MAX 70KTL3 MV MAX 80KTL3 M...

Страница 36: ...e accordance with the disposal regulations for electronic waste which apply at the installation site at that time Ensure that the old unit and where applicable any accessories are disposed of in a pro...