50
STEP 2 : ORIFICE CHANGE
Natural Gas
Propane Gas
4948EL4001B
4948EL4002B
Kit contents:
Orifice (Dia. = 1,613mm, for Propane Gas)
Conversion Label
Instruction Sheet
Plate label
8mBar for natural, 13mBar for propane
NCU
PCU
Remove 2 screws.
Disassemble the pipe assembly.
Replace Natural Gas orifice with Propane Gas orifice.
Loosen the lock nut and adjust the regulator
adjustment screw down to the closed position.
Verify the manifold pressure and tighten the lock nut.
Opened
Lock nut
Closed
Full open
Adjustment screw
Close
Adjustment screw
Orifice
The dryer is shipped from the factory set up and adjusted to operate on natural gas. It can be converted to operate on
propane (LPG). The conversion kit may be sold only to a licensed gasfitter, and must be performed ONLY by a licensed
gasfitter. This is not a do-it-yourself.
Note
STEP 1 : VALVE SETTING
Conversion must be made by a qualified technician.
Changing orifices and gas valve adjustments improperly can result in an explosion and/or fire.
WARNING
14
CHANGE GAS SETTING (NATURAL GAS, PROPANE GAS)
www.groupdynamics-laundry.com